Validación de un método de análisis para la determinación de raloxifeno en una formulación cubana / Validation of an analysis method to determine raloxifene in a Cuban formulation
Rev. cuba. farm
; 48(1)ene.-mar. 2014. graf, tab
Article
em Es
| CUMED
| ID: cum-63981
Biblioteca responsável:
CU1.1
Localização: CU1.1
RESUMEN
Introducción: el raloxifeno es un modulador selectivo del receptor estrogénico, perteneciente a la familia de los benzotiofenos. Los resultados de varios ensayos clínicos han mostrado que este fármaco reduce la pérdida del hueso en la espina dorsal y puede aumentar la masa del hueso en ciertos sitios. Objetivo: validar un método de análisis para la determinación de raloxifeno en una formulación cubana. Métodos: se desarrolló un método de análisis por cromatografía líquida de alta resolución. Se emplearon para ello una columna Lichrospher® 100, RP 18. Se utilizaron como fase móvil una mezcla de metanol-agua desionizada-trietanolamina (70:30:0,1) y detector ultravioleta a una longitud de onda de 286 nm. El flujo de la fase móvil fue de 1,5 mL/min y el volumen de inyección fue de 20 mL. Resultados: el método empleado para la cuantificación de raloxifeno en la formulación cubana resultó específico, preciso, exacto y lineal. Conclusiones: en las condiciones de estudio se demuestra que el método propuesto cumple con los parámetros de validación, por lo que puede ser utilizado en el control de la calidad de dicho medicamento(AU)
ABSTRACT
Introduction: raloxifene is a selective estrogen receptor modulator from the benzothiophene family. The results of several large clinical trials have shown that raloxifene reduces the rate of bone loss in the dorsal spine and may increase bone mass at certain sites. Objective: to validate an analytical method for determination of raloxifene in a Cuban formulation. Methods: a high performance liquid chromatography analytical method has been developed for the estimation of raloxifene in Cuban pharmaceutical dosage form. In this method, RP 18 Lichrospher 100 column with mobile phase consisting of methanol, de-ionized water and trietanolamine (ratio of 70:30:0.1) and 286 nm wavelength ultraviolet detector were used. The mobile phase flow was 1.5 mL/min and the injected volume reached 20 mL Results: the results showed that the suggested method for raloxifene quantitation was specific, accurate, precise and linear. Conclusions: under the studied conditions the analytic procedures can be applied for routine quality control analysis of raloxifene in pharmaceutical dosage form(AU)
Palavras-chave
Texto completo:
1
Coleções:
06-national
/
CU
Base de dados:
CUMED
Assunto principal:
Controle de Qualidade
/
Cromatografia Líquida de Alta Pressão
/
Cloridrato de Raloxifeno
Limite:
Humans
País/Região como assunto:
Cuba
Idioma:
Es
Revista:
Rev. cuba. farm
Ano de publicação:
2014
Tipo de documento:
Article