Resultados de la aplicación de un protocolo para el destete de la ventilación mecánica / Results of the application of a protocol for weaning from mechanical ventilation
Iglesias Almanza, Nuria; Pérez Parrado, Jorge; Guirola de la Parra, Julio; Pérez Gutiérrez, Eliodoro; Guerra Cruz, Guillermo; Varela Valdés, Arcides.
Afiliação
  • Iglesias Almanza, Nuria; Hospital Provincial Docente Dr Antonio Luaces Iraola. Ciego de Ávila. Cuba
  • Pérez Parrado, Jorge; Hospital Provincial Docente Dr Antonio Luaces Iraola. Ciego de Ávila. Cuba
  • Guirola de la Parra, Julio; Hospital Provincial Docente Dr Antonio Luaces Iraola. Ciego de Ávila. Cuba
  • Pérez Gutiérrez, Eliodoro; Hospital Provincial Docente Dr Antonio Luaces Iraola. Ciego de Ávila. Cuba
  • Guerra Cruz, Guillermo; Hospital Provincial Docente Dr Antonio Luaces Iraola. Ciego de Ávila. Cuba
  • Varela Valdés, Arcides; Hospital Provincial Docente Dr Antonio Luaces Iraola. Ciego de Ávila. Cuba
Mediciego ; 19(1)mar. 2013. tab, graf
Article em Es | CUMED | ID: cum-56858
Biblioteca responsável: CU421.1
RESUMEN
Con el objetivo de validar un protocolo de destete precoz y seguro para disminuir el tiempo de ventilación y las complicaciones asociadas a la ventilación mecánica, en el Hospital Provincial General Docente Dr. Antonio Luaces Iraola de Ciego de Ávila, se realizó un estudio pre experimental con grupo único. El universo estuvo constituido por 107 pacientes ventilados por más de 24 horas que ingresaron en el período comprendido de marzo del 2006 a febrero del 2010 y cumplieron los criterios de destete (por antecedentes patológicos antes del destete y predictores seleccionados en el protocolo. La aplicación del protocolo permitió minimizar los intentos fallidos en el destete, con lo cual disminuyó el tiempo de ventilación, el fallo del destete y las complicaciones asociadas a la ventilación mecánica (AU)
ABSTRACT
With the objective to validate a protocol of early and safe weaning to diminish the time of ventilation and the complications associated to mechanical ventilation, in the Provincial Teaching Hospital Dr. Antonio Luaces Iraolafrom Ciego de Avila, a pre experimental study with unique group was carried out. The universe was constituted by 107 patients ventilated for more than 24 hours from March 2006 to February 2010 and fulfilled the criteria of weaning (by pathological antecedents before the weaning and predictors selected in the protocol).The protocol application allowed to diminish vain attempts in the weaning, which it reduced the ventilation time , the weaning failure and the complications associated to mechanical ventilation (AU)