Your browser doesn't support javascript.
loading
Espesor corneal central en el glaucoma crónico simple / Central corneal thickness in chronic simple glaucoma
Lorenzo Ojeda, Elizabet; Suárez Pérez, Juana Caridad.
Afiliação
  • Lorenzo Ojeda, Elizabet; Hospital Militar Central Dr. Luis Díaz Soto. La Habana. Cuba
  • Suárez Pérez, Juana Caridad; Hospital Militar Central Dr. Luis Díaz Soto. La Habana. Cuba
Rev. cuba. med. mil ; 41(2): 160-166, mayo-jun. 2012.
Article em Es | CUMED | ID: cum-54930
Biblioteca responsável: CU1.1
RESUMEN
Objetivo: determinar si el espesor corneal central es un factor a considerar en el manejo de los pacientes con glaucoma crónico simple. Métodos: se realizó un estudio de casos y controles: un grupo con 100 pacientes con glaucoma crónico simple y otro con igual número de pacientes (personas sanas que acudieron a consulta por síntomas de astenopía ocular). Resultados: la presión intraocular aumentó de manera proporcional con el espesor corneal central con diferencias significativas (p= 0,000) entre ambos grupos. Con el aumento de la relación copa-disco, disminuye el espesor corneal central (p= 0,04 y 0,008). Se encontraron cifras más bajas de espesor corneal central en el grupo de casos. Conclusiones: el espesor corneal central fue directamente proporcional a los niveles de presión intraocular e inversamente proporcional a la relación copa-disco, por lo que es un factor a considerar en el manejo del glaucoma crónico simple(AU)
ABSTRACT
Objective: determine whether central corneal thickness is a factor to be considered in the management of patients with chronic simple glaucoma. Methods: a case-control study was conducted with a group of 100 patients with chronic simple glaucoma and a group of 100 healthy persons who presented with symptoms of visual asthenopathy. Results: increase in intraocular pressure was proportional to central corneal thickness, with significant differences (p= 0.000) between the two groups. As the cup-disc ratio increases, central corneal thickness decreases (p= 0.04 and 0.008). Lower central corneal thickness values were found in the case group. Conclusions: central corneal thickness was directly proportional to intraocular pressure levels, and inversely proportional to cup-disc ratio. It is therefore a factor to be considered in the management of chronic simple glaucoma(AU)
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Glaucoma de Ângulo Aberto / Pressão Intraocular Tipo de estudo: Observational_studies Limite: Female / Humans / Male Idioma: Es Revista: Rev. cuba. med. mil Ano de publicação: 2012 Tipo de documento: Article
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Glaucoma de Ângulo Aberto / Pressão Intraocular Tipo de estudo: Observational_studies Limite: Female / Humans / Male Idioma: Es Revista: Rev. cuba. med. mil Ano de publicação: 2012 Tipo de documento: Article