Comparação entre métodos de análise da composição corporal: síndrome de Down x desenvolvimento típico / Comparison of methods of body composition: Down syndrome x typical developmental
Semina cienc. biol. saude
; 39(2): 103-108, jul 2018. tab
Article
em Pt
| LILACS
| ID: biblio-988347
Biblioteca responsável:
BR512.1
Localização: BR512.1
RESUMO
Este estudo buscou comparar as médias do percentual de gordura (%G) e do índice de massa corporal (IMC) entre três métodos distintos de análise da composição corporal em adolescentes com desenvolvimento típico (GC) e com síndrome de Down (GSD). Para tal, contou-se com uma amostra de 60 adolescentes (30 GSD e 30 GC), de ambos os sexos, com idades entre 11 e 14 anos. Na avaliação e comparação do %G utilizou-se as bioimpedâncias elétricas de modelo tetrapolar, de membros superiores (OMRON®) e de membros inferiores (TANITA®) e, para o IMC a bioimpedância tetrapolar, a TANITA® e fórmula antropométrica. Os resultados demonstraram diferenças entre os métodos utilizados, tanto para a percentagem de gordura (GC x2= 28,78, p=0,000; GSD x2= 10,85, p=0,004) como para o cálculo do IMC (GC x2= 7,65, p = 0,22; GSD x2= 6,655, p=0,036), sendo superior no GSD. Portanto, conclui-se que, a bioimpedância tetrapolar continua sendo o melhor método para mensuração da percentagem de gordura e do IMC havendo diferenciação nos dados apresentados por outros modelos de aferição.
ABSTRACT
This study sought to compare the means of the fat percentage (BF%) and body mass index (BMI) between three different methods of body composition in teenager with typical developmental (GC) and Down syndrome (GSD). To this end, counted on the sample of 60 teenager (30 GSD and 30 GC), of both sexes, aged between 11 and 14 years. The assessment and comparison of BF% was used electric bioimpedance of quadrupole model, the upper limbs (OMRON®) and lower limbs (TANITA®) and for BMI, the electric bioimpedance of quadrupole model, the TANITA® and anthropometric formula. The results showed difference between the methods used, both the percentage of fat (BF x2 = 28.78, p = 0.000; GSD x2 = 10.85, p = 0.004) and for the calculation of BMI (GC x2 = 7.65, p = 0.22; GSD x2 = 6.655, p = 0.036), higher than the GSD. Therefore, it is concluded that the tetrapolar bioimpedance remains the best method to measure body fat percentage and BMI there differentiation in the data presented by other measurement models
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Composição Corporal
/
Impedância Elétrica
/
Síndrome de Down
Limite:
Adolescent
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Semina cienc. biol. saude
Assunto da revista:
BIOLOGIA
/
MEDICINA
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil