Your browser doesn't support javascript.
loading
Utilidad clínica del Antígeno Carcinoembrionario (ACE), Tomografía convencional (TC) y PET-CT en el diagnóstico de adenocarcinoma colorrectal recidivante / Clinical utility of Carcinoembryonic Antigen (ACE), conventional tomography (CT) and PET-CT in the diagnosis of recurrent colorectal adenocarcinoma
Tapia Baca, J; Tapia Mejía, J; Maldonado Noboa, I; Urquizo Romo, D; Martínez Nuñez, A; Segura Fernández, G; Troya Zuleta, A; Villacís Mora, P.
Afiliação
  • Tapia Baca, J; Hospital de Especialidades Carlos Andrade Marín. Unidad de Coloproctología. Quito. EC
  • Tapia Mejía, J; Hospital de Especialidades Carlos Andrade Marín. Unidad de Coloproctología. Quito. EC
  • Maldonado Noboa, I; Hospital de Especialidades Carlos Andrade Marín. Unidad de Oncología. Quito. EC
  • Urquizo Romo, D; Hospital de Especialidades Carlos Andrade Marín. Unidad de Oncología. Quito. EC
  • Martínez Nuñez, A; Hospital de Especialidades Carlos Andrade Marín. Unidad de PET - CT. Quito. EC
  • Segura Fernández, G; Hospital de Especialidades Carlos Andrade Marín. Unidad de PET - CT. Quito. EC
  • Troya Zuleta, A; Hospital de Especialidades Carlos Andrade Marín. Unidad de PET - CT. Quito. EC
  • Villacís Mora, P; Hospital de Especialidades Carlos Andrade Marín. Unidad de PET - CT. Quito. EC
Cambios rev. méd ; 16(1): 14-19, ene. - 2017. tab., graf., ilus
Article em Es | LILACS | ID: biblio-981442
Biblioteca responsável: EC162.1
ABSTRACT

Introduction:

Colorectal cancer is one of the most prevalent tumors in the world. In the surveillance setting of recurrent colorectal cancer, laboratory test like carncinoembryonic antigen (CEA) and imaging tests like computed tomography (CT) and positron emission tomography (PET/CT) are available. We performed this study to establish the predictive accuracy of these tests to an early identification of recurrent colorectal cáncer. Materials and

Methods:

Thirty six patients at stages I , III and IV, after single metastasis resection of colorectal cáncer were identified. We assessed the utility of CEA, CT and PET-CT in the follow-up of these patients to improve the diagnosis of recurrent disease.

Results:

Of 36 studied patients, 27 /75%) had recurrence; the median age was 61 year-old and the median lap-time 16 months. The PET PET/CT scan obtained the following

results:

sensitivity 96.7%, specificity 88.9%, positive predictive value 96.3%, negative predictive value 88.9%, positive likekihood ratio 8.7 and negative likelihood ratio 0.04.

Discusion:

The best tool to make diagnosis of colorectal cancer and its recurrence is PET­CT, however, none of these tests could make the diagnosis by themselves. It has to be confirmed by histopathologic studies plus other exams.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Antígeno Carcinoembrionário / Neoplasias do Colo / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Female / Humans / Male Idioma: Es Revista: Cambios rev. méd Assunto da revista: MEDICINA / SAUDE PUBLICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Equador País de publicação: Equador
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Antígeno Carcinoembrionário / Neoplasias do Colo / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Female / Humans / Male Idioma: Es Revista: Cambios rev. méd Assunto da revista: MEDICINA / SAUDE PUBLICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Equador País de publicação: Equador