Your browser doesn't support javascript.
loading
Medições de implantes através de suas imagens radiográficas / Measurements of implants through their radiographic images
Rio de Janeiro; s.n; 2009. 39 p. ilus.
Thesis em Pt | BBO | ID: biblio-913796
Biblioteca responsável: BR1366.1
Localização: BR1366.1; 616.314, B662, TO790
RESUMO
A morfometria in vivo dos implantes dentários poderá permitir a identificação do tipo de implante usado. O objetivo deste estudo foi comparar as medidas dos implantes dentários com as medidas das suas imagens radiográficas digitais e estabelecer as suas respectivas correlações, utilizando um programa de computador para realizar as mensurações das imagens radiográficas. Para isso foram utilizados seis implantes de cinco fabricantes, com diâmetro da plataforma variando de 3,5 a 4,6 mm e comprimento variando de 8,5 a 14 mm, medidos com um paquímetro digital. Os implantes foram radiografados com as películas periapicais em três angulações diferentes, zero, 20 e 40 graus em relação ao plano do objeto junto a uma esfera adotada como padrão de calibração radiográfica. As radiografias geradas foram digitalizadas e calibradas e medidas computacionalmente. Estas medidas obtidas foram então correlacionadas com as medidas dos implantes dentários, obtidas através do paquímetro digital. Os resultados expressaram que a) A comparação das medidas dos implantes com as medidas das suas imagens radiográficas, calibradas no mesmo sentido do padrão nas diferentes angulações não foram estatisticamente diferentes; b) As medidas das imagens obtidas com a angulação de zero, 20 e 40 graus não apresentaram distorção apreciável entre si, quando calibradas no mesmo sentido do padrão; c) Houve forte correlação entre as medidas dos implantes e das suas imagens radiográficas, quando calibradas no mesmo sentido do padrão (r = 0,99); d) O programa desenvolvido para mensuração de radiografias periapicais permitiu a realização das medidas com precisão em variações de até 40 graus de angulação do filme em relação ao implante, quando calibradas no mesmo sentido do padrão, provando que o paralelismo é importante, porém não indispensável na identificação de implantes.
ABSTRACT
The in vivo morphometry of dental implants may allow identification of the type of implant used. The objective of this study was to compare the measurements of dental implants with the measurements of their digital radiographic images and to establish their respective correlations, using a computer program to perform the measurements of the radiographic images. For this, six implants of five manufacturers were used, with platform diameter varying from 3.5 to 4.6 mm and length ranging from 8.5 to 14 mm, measured with a digital caliper. The implants were radiographed with the periapical films at three different angles, zero, 20 and 40 degrees to the plane of the object next to a sphere adopted as a radiographic calibration standard. The radiographs generated were digitalized and calibrated and measured computationally. These measurements were then correlated with the measurements of dental implants obtained through the digital caliper. The results showed that a) The comparison of the measurements of the implants with the measurements of their radiographic images, calibrated in the same direction of the pattern in the different angulations were not statistically different; b) The measurements of the obtained images with the zero, 20 and 40 degrees angulation did not show appreciable distortion among themselves, when calibrated in the same sense of the standard; c) There was a strong correlation between the measurements of the implants and their radiographic images, when calibrated in the same direction as the standard (r = 0.99); d) The program developed for the measurement of periapical radiographs allowed measurements to be performed accurately at variations of up to 40 degrees of film angulation in relation to the implant, when calibrated in the same sense as the standard, proving that parallelism is important, but not indispensable in the identification of implants
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 06-national Base de dados: BBO Assunto principal: Prostodontia / Radiografia Dentária / Implantes Dentários / Prótese Dentária Fixada por Implante Idioma: Pt Ano de publicação: 2009 Tipo de documento: Thesis País de publicação: Brasil
Texto completo: 1 Coleções: 06-national Base de dados: BBO Assunto principal: Prostodontia / Radiografia Dentária / Implantes Dentários / Prótese Dentária Fixada por Implante Idioma: Pt Ano de publicação: 2009 Tipo de documento: Thesis País de publicação: Brasil