Estimulação óssea promovida pela rugosidade na superfície de implantes dentais – estudo experimental in vivo / Bone stimulation promoted by dental implant surface roughness – an in vivo experimental study
Gehrke, Sérgio Alexandre.
Afiliação
  • Gehrke, Sérgio Alexandre; PUC/RS. BR
ImplantNews ; 9(6a): 181-187, 2012. ilus, tab, graf
Article em Pt | LILACS, BBO | ID: biblio-851009
Biblioteca responsável: BR243.1
Localização: Br243.1
RESUMO
O objetivo desse estudo foi avaliar a influência do tratamento superficial dos implantes na estimulação celular durante o período de osseointegração em diferentes tempos em tíbias de coelhos. Foram utilizados 24 implantes cilíndricos, sendo 12 sem tratamento de superfície (grupo 1) e outros 12 com tratamento superficial através de jateamento com micropartículas de óxido de titânio e ataque ácido (grupo 2). Esses foram inseridos em seis coelhos New Zeland na tíbia bilateralmente (dois por tíbia). Após a eutanásia, as tíbias foram removidas e destinadas ao teste de torque de remoção e processamento histológico. Os resultados para o torque de remoção no período de 30 dias foram 9,3% e, após 60 dias, 21,2% maiores para o grupo 2. Uma diferença estatisticamente significante entre os grupos foi encontrada (p < 0,001) nas amostras com 60 dias do grupo 2. Histologicamente, ambos os grupos apresentaram adequada biocompatibilidade e osseocondução com neoformação óssea nas regiões cortical e medular da tíbia. Na avaliação por MEV, nos dois tempos, os implantes do grupo 1 apresentaram menor retenção de tecido ósseo sobre a superfície e pouca organização estrutural desse osso, enquanto que, nos implantes do grupo 2, houve maior integração óssea em quantidade e melhor organização desse tecido retido. Baseado nos resultados obtidos, concluiu-se que a microestrutura superficial influencia diretamente na estimulação óssea, promovendo maior adesão do tecido ósseo em quantidade e melhor organização estrutural nos períodos estudados, quando comparado com implantes lisos.
ABSTRACT
The objective of this study was to evaluate the influence of implant surface treatment on cellular stimulation during ossoeintegration at different periods using the rabbit tibiae model. Twenty-four cylindrical implants were used control group (G1, n =12), and an experimental group (G2) blasted with acid-etched, titanium oxide microparticles inserted bilaterally at the proximal tibiae of six New Zealand rabbits(two per tibia). After animal euthanasia at 30 and 60 days, the tibiae were removed for removal torque test and histological processing. Results for the removal torque with 30 days were 9.3% and after 60 days, 21.2% higher for G2. A statistically significant difference between groups was found (p < 0.001) in samples with 60 days in G2. Histologically, both groups had adequate biocompatibility, with osseoconduction and osteogenesis at cortical and medullary regions. SEM analysis, in both periods demonstrated that G1 implantshad a lower boneretention on the surface and little structuralorganization, while in G2, greater amount of bone integration and better organization was observed. Based on these results, it can be said that implant surface microstructure directly influences on bone stimulation, promoting an increased bone adhesion in quantity and a better structural organization during the periods studied compared with machined implants
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: BBO / LILACS Assunto principal: Implantes Dentários / Osseointegração Limite: Animals Idioma: Pt Revista: ImplantNews Assunto da revista: ODONTOLOGIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil