Your browser doesn't support javascript.
loading
Biomechanical tools to study dental implants: a literature review / Ferramentas biomecânicas aplicadas no estudo dos implantes dentários: revisão de literatura
TRIBST, João Paulo Mendes; DAL PIVA, Amanda Maria de Oliveira; BORGES, Alexandre Luiz Souto.
Afiliação
  • TRIBST, João Paulo Mendes; São Paulo State University-Unesp. Institute of Science and Technology. São José dos Campos. BR
  • DAL PIVA, Amanda Maria de Oliveira; São Paulo State University-Unesp. Institute of Science and Technology. São José dos Campos. BR
  • BORGES, Alexandre Luiz Souto; São Paulo State University-Unesp. Institute of Science and Technology. São José dos Campos. BR
Braz. dent. sci ; 19(4): 5-11, 2016. ilus
Article em En | LILACS, BBO | ID: biblio-850481
Biblioteca responsável: BR243.1
Localização: BR243.1
RESUMO
Desde 1980, o comportamento biomecânico dos implantes dentários tem recebido importância em relação às falhas neste sistema de reabilitação devido à sobrecarga oclusal. Através de ferramentas da bioengenharia, vários estudos têm sido realizados para elucidar a influência de diversos fatores sobre a resposta biológica. Ferramentas da bioengenharia, como a análise de elementos finitos (FEA), a extensometria (SGA), a fotoelasticidade (PEA) e a correlação de imagem digital (DIC) são amplamente utilizadas na extrapolação clínica de possíveis soluções mecânicas para implantodontia. Esta trabalho teve como objetivo investigar os métodos de análise de tensão disponíveis para o estudo do comportamento dos implantes dentários através de uma revisão da literatura. Esta revisão começou com uma pesquisa no PubMed dos estudos mais antigos de cada metodologia correlacionadas ao comportamento biomecânico de implantes dentários até 2016. As metodologias FEA, SGA, PEA e DIC são capazes de elucidar o comportamento mecânico deste sistema de reabilitação. No entanto, a combinação de dois ou mais métodos fornece explicações mais detalhadas e evita limitações de uma única metodologia.
ABSTRACT
Since 1980, the biomechanical behavior of dental implants has received importance regarding the issue of failure in this rehabilitation system due to occlusal overload. Through bioengineering tools, several studies have been conducted to answer about the influence of different factors on the biological response. Bioengineering tools such as finite element analysis (FEA), strain gauge (SGA), photoelasticity (PEA) and digital image correlation (DIC) are widely inspiring clinical extrapolation of possible solutions in the mechanics of implantology. This study has aimed to investigate the available stress analysis methods to study dental implants’ behavior through a literature review. This review started with a PubMed search from the mostly old studies of each methodology correlated to biomechanical behavior of dental implants used with dental implants studies until 2016. FEA, SGA, PEA and DIC methodologies are capable to elucidate the mechanical behavior of this rehabilitation system. However, the combination of two or more methods gives more detailed explanation and avoids limitations of a single methodology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: BBO / LILACS Assunto principal: Análise de Elementos Finitos / Implantação Dentária Idioma: En Revista: Braz. dent. sci Assunto da revista: ODONTOLOGIA / Sa£de Bucal Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: BBO / LILACS Assunto principal: Análise de Elementos Finitos / Implantação Dentária Idioma: En Revista: Braz. dent. sci Assunto da revista: ODONTOLOGIA / Sa£de Bucal Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil