Manejo de vía aérea difícil en paciente con bocio maligno gigante: Reporte de caso / Case report: Difficult airway management in a patient with giant malignant goiter
Rev. chil. anest
; 50(5): 700-703, 2021. ilus
Article
em Es
| LILACS
| ID: biblio-1532899
Biblioteca responsável:
CL1.1
ABSTRACT
We present the case of an adult patient with a malignant goiter, treated in our center, where airway management is perfor- med by an awake intubation technique with sedation. The patient, with great compromise and deviation from the midline of the airway, was managed with a High-Flow Nasal Cannula (CNAF) during its manipulation, helping to avoid desaturation events during the intubation procedure, associated with the administration of monitored sedation.
RESUMEN
Presentamos el caso de una paciente adulto con bocio maligno, tratada en nuestro centro, donde se realiza manejo de la vía aérea con la intubación traqueal vigil con sedación. La paciente, con gran compromiso y desviación de línea media de la vía aérea, es apoyada con Cánula Nasal de Alto Flujo (CNAF) durante la manipulación de ésta, ayudando a no presentar eventos de desaturación durante el procedimiento de intubación, asociada a la administración de sedación monitorizada.