A profundidade do tubo orotraqueal em crianças predita por fórmulas apresenta boa concordância com o posicionamento verificado pela radiografia? / Does the endotracheal tube insertion depth predicted by formulas in children have a good concordance with the ideal position observed by X-ray?
Santos, Dayanna Letícia Silva; Andrade, Paulo Douglas de Oliveira; Gomes, Evelim Leal de Freitas Dantas.
Afiliação
  • Santos, Dayanna Letícia Silva; Universidade Federal do Pará. Faculdade de Fisioterapia e Terapia Ocupacional. Belém. BR
  • Andrade, Paulo Douglas de Oliveira; Unidade de Terapia Intensiva Pediátrica. Fundação Hospital de Clínicas Gaspar Vianna. Belém. BR
  • Gomes, Evelim Leal de Freitas Dantas; Universidade Nove de Julho. São Paulo. BR
Rev. bras. ter. intensiva ; 32(2): 295-300, Apr.-June 2020. tab, graf
Article em En, Pt | LILACS | ID: biblio-1138477
Biblioteca responsável: BR1.1
RESUMO
RESUMO

Objetivo:

Avaliar a efetividade dos diferentes métodos que estimam a profundidade de inserção do tubo orotraqueal em crianças.

Métodos:

Estudo observacional e transversal, no qual foram incluídas crianças entre 29 dias e 2 anos, internadas em uma unidade de terapia intensiva pediátrica e ventiladas mecanicamente. Foram avaliadas as fórmulas baseadas na altura [(altura/10) + 5], no diâmetro interno do tubo (tubo orotraqueal × 3) e peso (peso + 6), verificando-se qual delas apresentou melhor concordância com a profundidade ideal de inserção do tubo orotraqueal avaliado por radiografia.

Resultados:

A correlação entre a fórmula da altura e a profundidade ideal observada no raio X foi forte, com r = 0,88, p < 0,05 e o coeficiente de correlação de concordância de 0,88; a correlação do peso com a profundidade no raio X foi de r = 0,75, p < 0,05 e coeficiente de correlação de concordância de 0,43; e a fórmula do tubo orotraqueal × profundidade no raio X foi de r = 0,80, p < 0,05 e coeficiente de correlação de concordância de 0,78. A análise de concordância de Lin mostrou que as medidas apresentaram concordância fraca (< 0,90).

Conclusão:

As fórmulas que estimam a profundidade de inserção do tubo orotraqueal em crianças apresentaram-se pouco precisas e discordantes com o método padrão-ouro de avaliação pelo raio X, com necessidade da criação de um novo método, baseado nas variáveis antropométricas (peso e altura) e na idade, que seja eficaz para guiar os profissionais de saúde das unidades de terapia intensiva pediátricas, no momento da intubação.
ABSTRACT
ABSTRACT

Objective:

To evaluate the effectiveness of the different formulas for estimating the insertion depth of an endotracheal tube in children.

Methods:

This was an observational and cross-sectional study that included children between 29 days and 2 years of age who were hospitalized in a pediatric intensive care unit and mechanically ventilated. The formulas based on height [(height/10) + 5], the inner diameter of the tube (endotracheal tube × 3), and weight (weight + 6) were evaluated to determine which of them showed better concordance with the ideal insertion depth of the endotracheal tube as evaluated by X-ray.

Results:

The correlation between the height-based calculation and the ideal depth observed on X-ray was strong, with r = 0.88, p < 0.05, and a concordance correlation coefficient of 0.88; the correlation between the weight-based calculation and depth on X-ray was r = 0.75, p < 0.05, and concordance correlation coefficient 0.43; and the correlation between endotracheal tube diameter-based calculation and depth on X-ray was r = 0.80, p < 0.05, and concordance correlation coefficient 0.78. Lin's concordance correlation analysis indicated that the measurements showed weak concordance (< 0.90).

Conclusion:

The formulas that estimate the insertion depth of the endotracheal tube in children were not accurate and were discordant with the gold-standard method of X-ray evaluation. There is a need for a new method based on anthropometric variables (weight and height) and age that is effective in guiding health professionals of pediatric intensive care units at the time of intubation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Respiração Artificial / Unidades de Terapia Intensiva Pediátrica / Intubação Intratraqueal Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En / Pt Revista: Rev. bras. ter. intensiva Assunto da revista: TERAPIA INTENSIVA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Respiração Artificial / Unidades de Terapia Intensiva Pediátrica / Intubação Intratraqueal Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En / Pt Revista: Rev. bras. ter. intensiva Assunto da revista: TERAPIA INTENSIVA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil