ABSTRACT

Objectives:

to assess discrepancies in cephalometric measurements from digital lateral radiography and virtual cone-beam computed assisted tomography cephalogram. materials and

methods:

forty digital lateral radiographs and forty virtual cephalograms obtained by cone-beam computed assisted tomography were analyzed, corresponding to forty patients from the Instituto de Diagnóstico Maxilofacial in Lima, Peru. the principal investigator, who had been previously calibrated, made two measurements within a timespan of fifteen days using the analysis of Steiner and the NemoCeph software, and the difference between the obtained measurements was evaluated to determine if it was significant.

results:

for digital lateral radiographs the difference varied between 0.00º - 0.45º and 0.01mm - 0.16mm, with statistical significance for distance between Pg and NB for lateral virtual cephalograms between 0.03º - 0.73º and 0.01mm - 0.43mm, with statistical significance for SE distance. the comparison between the two types of image in the first measurement showed a difference of 0.08º - 1.15º and 0.00mm - 1.43mm with statistical significance for four angular measurements and one linear. the comparison between the two types of image in the second measurement showed a difference of 0.13º - 1º and 0.02mm - 1.32mm with a statistically significant difference for three angular and two linear measurements.

conclusions:

the difference between the two types of image is minimal; both evaluated methods can be used effectively.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Processamento de Imagem Assistida por Computador / Radiografia Dentária Digital / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Observational_studies Limite: Humans País/Região como assunto: America do sul / Peru Idioma: En Revista: J. oral res. (Impresa) Assunto da revista: ODONTOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Peru País de publicação: Chile

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Processamento de Imagem Assistida por Computador / Radiografia Dentária Digital / Tomografia Computadorizada de Feixe Cônico Tipo de estudo: Observational_studies Limite: Humans País/Região como assunto: America do sul / Peru Idioma: En Revista: J. oral res. (Impresa) Assunto da revista: ODONTOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Peru País de publicação: Chile