Utilidad de la prueba de fuga peritubo para la seguridad de la extubación / Usefulness of the test of leak around the tube for patient safety
Rev. cuba. anestesiol. reanim
; 19(1): e583, ene.-abr. 2020. tab
Article
em Es
| LILACS, CUMED
| ID: biblio-1093128
Biblioteca responsável:
CU1.1
RESUMEN
Introducción:
La prueba de fuga de aire peritubo no es invasiva. Es relativamente fácil de realizar y proporciona una indicación de la permeabilidad de la vía respiratoria superior.Objetivo:
Evaluar la eficacia de la prueba de fuga peritubo, medidas de modo cualitativas y cuantitativa, para la seguridad de la extubación.Método:
Se realizó un estudio descriptivo, prospectivo de corte transversal de los pacientes de cualquier género, programados para intervención quirúrgica por microcirugía laríngea, cirugía para bocio endotoraxico, cirugía maxilofacial y aquellos con antecedentes de intubación difícil que requirieron más de tres intentos de intubación y/o uso de conductores o guías. La muestra estuvo conformada por 52 pacientes que cumplieron los criterios de selección. El análisis estadístico se realizó mediante el cálculo de medidas para variables cualitativas y para las cuantitativas el Chi-cuadrado de Pearson (x2).Resultados:
El grupo con mayor frecuencia fueron los menores de 40 años. Predominó el sexo masculino. El tubo 7,5 fue el más utilizado (50 por ciento). Los resultados de la concordancia entre la prueba cualitativa y cuantitativa según presencia o no de fuga de aire peritubo fue de 90,4 por ciento respectivamente. Las complicaciones según pruebas fueron escasas.Conclusiones:
Ambas pruebas constituyen herramientas útiles para el diagnóstico de obstrucción de la vía respiratoria durante la extubación. La modalidad cualitativa resultó ser tan eficaz como la cuantitativa y más fácil de reproducir para los operadores en el estudio(AU)ABSTRACT
Introduction:
The air leak test around the endotracheal tube is not invasive. It is relatively easy to perform and provides an indication of the permeability of the upper airway.Objective:
To evaluate the effectiveness of the air leak" test around the endotracheal tube, qualitatively and quantitatively measured, for the safety of extubation.Method:
A descriptive, prospective and cross-sectional study was carried out with patients of any gender scheduled for surgical intervention by laryngeal microsurgery, surgery for endotoxic goiter, maxillofacial surgery, and those with a history of difficult intubation that required more than three attempts at intubation and/or the usage of drivers or guides. The sample consisted of 52 patients who met the selection criteria. Statistical analysis was performed by calculating measures for qualitative variables, while for quantitative variables, Pearson's chi-square (x2) was used.Results:
The group with more frequency was represented by those under 40 years. The male sex prevailed. The 7.5 tube was the most used (50 percent). The results of the concordance between the qualitative and quantitative test according to the presence or absence of air leak around the tube was 90.4 percent, respectively. Complications based on the tests were scarce.Conclusions:
Both tests are useful tools for the diagnosis of airway obstruction during extubation. The qualitative modality proved to be as effective as the quantitative and easier to reproduce for the operators in the study(AU)Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
CUMED
/
LILACS
Assunto principal:
Procedimentos Cirúrgicos Operatórios
/
Extubação
Tipo de estudo:
Guideline
/
Observational_studies
/
Prevalence_studies
/
Qualitative_research
/
Risk_factors_studies
Limite:
Humans
Idioma:
Es
Revista:
Rev. cuba. anestesiol. reanim
Assunto da revista:
ANESTESIOLOGIA
Ano de publicação:
2020
Tipo de documento:
Article
País de afiliação:
Cuba
País de publicação:
Cuba