Validez factorial del cuestionario sobre trato digno en enfermería / Review of the effect of uncertainty in adults with type 2 diabetes mellitus
Rev. enferm. Inst. Mex. Seguro Soc
; 27(2): 97-104, Abr-Jun 2019. tab, graf
Article
em Es
| LILACS, BDENF
| ID: biblio-1015238
Biblioteca responsável:
MX346.1
RESUMEN
Introducción:
Ofrecer un trato digno a los pacientes es un componente central en la calidad de los servicios de salud, por lo que su medición válida resulta altamente relevante.Objetivo:
Evaluar la validez de constructo del cuestionario Trato digno en enfermería, desarrollado por la Secretaría de Salud en México.Métodos:
Estudio observacional, transversal y analítico. Se seleccionó una muestra por conveniencia, la cual estuvo constituida por 355 pacientes atendidos en el 100% de los 89 centros de salud.Resultados:
Hubo en promedio de puntuaciones altas de trato digno (0.84, rango 0-1)), el ajuste del modelo resultó adecuado al considerar diversos índices NNFI = 0.99; NFI = 0.98; CFI = 0.99; RMSEA = 0.04; PNFI = 0.70 y chi cuadrada normada = 2.37. Un hallazgo notable fue la correlación positiva (p < 0.05) entre las dimensiones de relaciones humanas con la dimensión comunicativa (r = 0.95), relaciones humanas con la dimensión interior de la persona (r = 0.90) y dimensión comunicativa con dimensión interior de la persona (r = 0.90).Conclusión:
Se comprobó la validez de constructo del cuestionario Trato digno en enfermería.ABSTRACT
Introduction:
Providing dignified care to patients is one of the main components in health care quality, which is why measuring it is really important.Objective:
To evaluate the construct validity of the Dignified Care questionnaire in nursing, this was developed by the Secretaría de Salud (Mexico's Health Secretary).Methods:
Observational, cross-sectional, and analytical study. 355 patients, attended in all the 89 health centers, were selected by convenience sampling.Results:
There were on average high punctuations of dignified care (0.84, range 0,1). The adjustment of the model was appropriate, since several indexes were considered NNFI = 0.99; NFI = 0.98; CFI = 0.99; RMSEA = 0.04; PNFI = 0.70 and normalized chi squared = 2.37. A remarkable finding was the positive correlation between the following dimensions (p < 0.05) human relations with communication (r = 0.95), human relations with the patient's inner dimension (r = 0.90), and communication with the patient's inner dimension (r = 0.90).Conclusions:
Construct validity of the Dignified Care questionnaire in nursing was confirmed.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BDENF
/
LILACS
Assunto principal:
Indicadores de Serviços
/
Estudos Transversais
/
Coleta de Dados
/
Enfermagem
/
Direitos Civis
/
Indicadores de Qualidade em Assistência à Saúde
/
Governo Federal
/
Estudo Observacional
Tipo de estudo:
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
País/Região como assunto:
Mexico
Idioma:
Es
Revista:
Rev. enferm. Inst. Mex. Seguro Soc
Assunto da revista:
ENFERMAGEM
Ano de publicação:
2019
Tipo de documento:
Article
País de afiliação:
México
País de publicação:
México