Pletismografía en pacientes con bronquiectasias secundarias a tuberculosis en un hospital público de Lima, Perú / Plethysmography in patients with bronchiectasis secondary to tuberculosis in a public hospital in Lima, Peru
Acta méd. peru
; 35(4): 211-215, oct.-dic. 2018. tab
Article
em Es
|
LILACS-Express
| LILACS
| ID: biblio-1010917
Biblioteca responsável:
PE1.1
RESUMEN
Objetivo:
determinar las características de las pruebas de función pulmonar en pacientes con Bronquiectasias secundarias a Tuberculosis pulmonar en el Hospital Nacional Dos de Mayo (Lima, Perú) durante los años 2015 - 2016. Materiales ymétodos:
se realizó un estudio cuantitativo, observacional, descriptivo, retrospectivo. Se recolectó información de historias clínicas de pacientes con diagnóstico de bronquiectasias secundarias a tuberculosis pulmonar con pruebas de función pulmonar y otros variables asociadas.Resultados:
se revisaron 76 historias clínicas de pacientes con pruebas de función pulmonar. En espirometría encontramos que el 40.8% tenía patrón obstructivo y el 22.3% patrón restrictivo. En pletismografía se determinó que 61.8% tenía criterios de atrapamiento aéreo por volumen residual > 120% y que 9.2% tenía criterios de hiperinflación pulmonar por capacidad pulmonar total > 120%. Asimismo, se pudo encontrar cambios estadísticamente significativos en los valores de pletismografía luego del uso del broncodilatador.Conclusiones:
el patrón más frecuente fue el obstructivo con atrapamiento aéreo sin hiperinflación pulmonar.ABSTRACT
Objective:
To determine the characteristics of pulmonary function tests in patients with bronchiectasis secondary to pulmonary tuberculosis in Dos de Mayo National Hospital in Lima, Peru, during 2015 to 2016. Material andMethods:
This is a quantitative observational, descriptive, and retrospective study. Data from clinical records of patients diagnosed with bronchiectasis secondary to pulmonary tuberculosis and other associated variables was collected.Results:
Seventy-six clinical records with available data from pulmonary function tests were reviewed. With respect to spirometry we found that 40.8% had an obstructive pattern, and 22.3% had a restrictive pattern. When plethysmography was performed, it was determined that 61.8% had criteria for air trapping, because of having a >120% residual volume, and 9.2% had criteria for defining pulmonary hyperinflation due to a >120% total lung capacity. Also, statistically significant changes were found in plethysmography values after using bronchodilators.Conclusions:
The most frequent pattern in these patients was obstructive, with air trapping and no pulmonary hyperinflation.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Tipo de estudo:
Observational_studies
/
Risk_factors_studies
País/Região como assunto:
America do sul
/
Peru
Idioma:
Es
Revista:
Acta méd. peru
Assunto da revista:
MEDICINA
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Peru
País de publicação:
Peru