Application of sourceless efficiency calibration in activity measurement of gas source in Marinelli beaker / 中国辐射卫生
Chinese Journal of Radiological Health
; (6): 6-12, 2022.
Article
en Zh
| WPRIM
| ID: wpr-973569
Biblioteca responsable:
WPRO
ABSTRACT
Objective To optimize the Marinelli beaker with the simulation of Laboratory Sourceless Object Calibration Software (LabSOCS), to investigate the detection efficiency of HPGe detector in measuring noble gas, and to provide a reference for the measurement and optimization of noble gas effluent from nuclear power plants. Methods LabSOCS was used to establish a Marinelli beaker model to investigate the relationship of gamma ray detection efficiency of noble gas with gas components, gas density, size and volume of the Marinelli beaker, and the shape of source container. Results The gas components had little effect on the detection efficiency of the noble gas in the Marinelli beaker. The gas density had a relatively great effect on the detection efficiency of low-energy gamma ray. The Marinelli beaker of appropriate height and radius enabled the HPGe detector to get better measurement results. For the BE5030 HPGe detector, the highest detection efficiency of the Marinelli beakers of different volumes were observed at the location where the radius/height ratio was 0.7, and the optimal values of height and radius were given for the Marinelli beakers of different volumes. Conclusion Choosing Marinelli beaker of the appropriate size can improve the detection efficiency of noble gas in the effluent from nuclear power plants.
Texto completo:
1
Base de datos:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Radiological Health
Año:
2022
Tipo del documento:
Article