Your browser doesn't support javascript.
loading
Shielding calculation and discussion on high energy light source storage ring and synchrotron / 中华放射医学与防护杂志
Article en Zh | WPRIM | ID: wpr-884489
Biblioteca responsable: WPRO
ABSTRACT
Objective:To verify and discuss the consistency and applicability of the semi empirical formula and Monte Carlo simulation method in the radiation shielding calculation for high energy synchrotron radiation source.Methods:The semi empirical formula and Monte Carlo simulation were used to calculate the ambient dose equivalent outside of the shielding.Results:The ratio of Jenkins semi empirical formula result to Monte Carlo simulation result was 111%-153%. The ratio of Sakano semi empirical formula result to Monte Carlo simulation result was 201%.Conclusions:For a single shielding material, the semi empirical formula can be simple and conservative to complete the shielding calculation for high-energy electron accelerator. For a variety of shielding materials, Monte Carlo simulation method should be used.
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Radiological Medicine and Protection Año: 2021 Tipo del documento: Article
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Radiological Medicine and Protection Año: 2021 Tipo del documento: Article