Comparison of Plasma Components between Frozen Plasma and Fresh Frozen Plasma / 中国实验血液学杂志
Journal of Experimental Hematology
; (6): 615-619, 2021.
Article
en Zh
| WPRIM
| ID: wpr-880122
Biblioteca responsable:
WPRO
ABSTRACT
OBJECTIVE@#To compare the plasma components of frozen plasma (FP) and fresh frozen plasma (FFP).@*METHODS@#Twenty samples of FP and 20 samples of FFP from Beijing Red Cross Blood Center were randomly selected. Immediately after plasma melting, 12 plasma components including coagulation factor, fibrinolytic system and anticoagulation protein were detected, including activated partial thromboplastin time (APTT), prothrombin time (PT), coagulation factor Ⅷ (FⅧ) activity, coagulation factor Ⅴ (FⅤ) activity, fibrinogen(FIB) level, ADAMTS-13 activity, von Willebrand factor(vWF) activity, D-dimer (D-dimer, DD), fibrin degradation products (FDP), antithrombin (AT), protein C (PC), and protein S (PS). All these coagulation components between the two types of plasma were compared and analyzed.@*RESULTS@#Compared with FFP, APTT in FP was significantly prolonged(t=3.428, P0.05).@*CONCLUSION@#FP can substitute FFP in the treatment of some diseases, although it is lack of some coagulation factors and anticoagulation protein.
Texto completo:
1
Base de datos:
WPRIM
Asunto principal:
Plasma
/
Coagulación Sanguínea
/
Pruebas de Coagulación Sanguínea
/
Factores de Coagulación Sanguínea
/
Beijing
Límite:
Humans
País/Región como asunto:
Asia
Idioma:
Zh
Revista:
Journal of Experimental Hematology
Año:
2021
Tipo del documento:
Article