Ways to overcome non-draining indwelling pleural catheter in malignant pleural effusion
Med. j. malaysia
; : 555-557, 2019.
Article
en En
| WPRIM
| ID: wpr-825363
Biblioteca responsable:
WPRO
ABSTRACT
@#The indwelling pleural catheter (IPC) is a 16-Fr-multifenestrated catheter. It has become an accepted practice in the management of malignant pleural effusion, especially in patients with non-expandable lung. However, IPC blockage or not draining is common. A 53-year-old female with malignant pleural effusion presented to us with blocked IPC and symptomatic pleural loculation one month after IPC insertion. After failing saline flushing and low-pressure wall suction, intrapleural alteplase was instituted through the IPC with a favourable outcome, and she continued to drain daily thereafter. The present case highlights the safety of intrapleural alteplase via IPC in the non-expandable lung.