Diagnostic value of integrated ¹⁸F-fluoro-2-deoxyglucose positron emission tomography/computed tomography in recurrent epithelial ovarian cancer: accuracy of patient selection for secondary cytoreduction in 134 patients / 부인종양
Journal of Gynecologic Oncology
; : e36-2018.
Article
en En
| WPRIM
| ID: wpr-714690
Biblioteca responsable:
WPRO
ABSTRACT
OBJECTIVE: The aim of this study was to evaluate the diagnostic value of integrated 18F-fluoro-2-deoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT) for suspected recurrence of epithelial ovarian cancer (EOC) with non-disseminated lesions. METHODS: We retrospectively reviewed the medical records of recurrent EOC patients who underwent secondary cytoreduction from January 2000 to December 2013. A total of 134 patients underwent secondary cytoreduction after imaging with either 18F-FDG-PET/CT or contrast-enhanced computed tomography (CECT). RESULTS: In a patient-based analysis of 134 patients, 124 (92.5%) were confirmed to be positive for malignancy. Among 72 patients with suspected non-disseminated recurrence on 18F-FDG-PET/CT, 65 (89.0%) were confirmed to have recurrence, giving 98.5% sensitivity, 87.7% accuracy, and 88.9% positive predictive value (PPV). In the 65 patients with recurrence, residual tumor remained in 14 patients, giving an accuracy of patient selection for secondary cytoreduction of 69.4% (50/72) and it is higher than that of CECT (64.0%). In 169 lesions removed from patients who underwent preoperative 18F-FDG-PET/CT, 135 (79.9%) were confirmed to be positive for malignancy and 124 were accurately detected by 18F-FDG-PET/CT, giving 91.9% sensitivity, 81.1% accuracy, and 85.5% PPV. Foreign body granuloma was found in 33.3% of 21 lesions with false-positive 18F-FDG-PET/CT findings (7/21). The mean preoperative cancer antigen 125 (CA-125) level in false-positive patients was 28.8 U/mL. CONCLUSION: Compared with CECT, 18F-FDG-PET/CT shows higher sensitivity in lesion-based analysis and better accuracy of patient selection for secondary cytoreduction. However, there is still a need for integration of the results of 18F-FDG-PET/CT, CECT, and CA-125 levels to aid treatment planning.
Palabras clave
Texto completo:
1
Base de datos:
WPRIM
Asunto principal:
Neoplasias Ováricas
/
Recurrencia
/
Granuloma de Cuerpo Extraño
/
Registros Médicos
/
Estudios Retrospectivos
/
Selección de Paciente
/
Neoplasia Residual
/
Electrones
/
Procedimientos Quirúrgicos de Citorreducción
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
Límite:
Humans
Idioma:
En
Revista:
Journal of Gynecologic Oncology
Año:
2018
Tipo del documento:
Article