Dynamic digital radiography of hysterotubography combined with hydrotubation in dagnosis of utero-tub-al factors in infertility / 实用医学杂志
The Journal of Practical Medicine
; (24): 3216-3219, 2017.
Article
en Zh
| WPRIM
| ID: wpr-658467
Biblioteca responsable:
WPRO
ABSTRACT
Objective To analyze the diagnostic value of dynamic digital radiography of hysterotubography combined with hydrotubation in utero-tubal factors in infertility. Methods Totally 480 female patients with infertil-ity caused by utero-tubal factors from June 2015 to March 2017 were divided into group A and group B randomly. After the two groups were all examined by dynamic digital radiography of hysterotubography ,group A received man-ual push and group B hydrotubation. Results and safety of radiography of two groups were analyzed. Results Im-age definition of group B was higher than that of group A. Number of dots and adverse reaction were less in group B than those in group A(P<0.05),but procedural time was longer than that of group A(P<0.05). The difference in the diagnostic rates of the disease of two groups was not statistically significant(P>0.05). Conclusion Dynamic digital radiography of hysterotubography combined with hydrotubation has good diagnostic value in infertility caused by utero-tubal factors and less adverse reactions
Texto completo:
1
Base de datos:
WPRIM
Tipo de estudio:
Guideline
Idioma:
Zh
Revista:
The Journal of Practical Medicine
Año:
2017
Tipo del documento:
Article