The accuracy of puncture guided by intelligent positioning system using magnetic navigation / 中华医学超声杂志(电子版)
Chinese Journal of Medical Ultrasound (Electronic Edition)
; (12): 500-504, 2013.
Article
en Zh
| WPRIM
| ID: wpr-636056
Biblioteca responsable:
WPRO
ABSTRACT
Objective To assess the accuracy of puncture guided by intelligent positioning (IP) system using magnetic navigation.Methods Five prepared targeted models at three certain depth (100 mm,large depth) underwent puncture guided by intelligent positioning system using IP and conventional ultrasound (US),respectively.Puncture errors,the number of attempt and spent time were recorded and compared .Results For the targets at small,medium and large depth,the errors of IP was (1.88 ±1.18),(1.56 ±0.56) and (3.99 ±1.10) cm,and the errors of conventional US was (4.52 ±2.23),(4.49 ±1.73) and (3.93 ±2.19) cm respectively.The errors of IP were significantly less than those of conventional US at small(t=-2.345,P=0.047) and medium(t=-3.608,P=0.007) depth,but there was no statistically significant difference at large depth (t=0.058,P=0.955). In the IP group,there were statistically significant differences for puncture errors between the small and large depth,as well as between medium and large depth ( F =8.923,P =0.010).There was no statistically significant difference for the errors of IP between the small and medium depth (t=-1.927,P=0.501).For the targets at small,medium and large depth,each puncture was performed in single attempt when guided by IP and in 2,1 and 2 attempt when guided by conventional US .At small and large depth,the numbers of attempt of IP were significantly less than those of conventional US (U=-2.372,P=0.018;U=-2.39, P=0.032).Whereas at medium depth,there was no significant difference (U=-1.000,P=0.690).For the targets at small,medium and large depth,each puncture spent (21.20 ±2.39)s, (27.00 ±4.00)s and (31.80 ±3.83)s when guided by IP,and(45.20 ±9.68),(26.80 ±4.21) and (54.60 ±13.48)s when guided by conventional US.The spent time of IP was less than that with conventional US for small and large depth targets(t =-5.383, P =0.001;t =-3.637, P =0.007).Whereas no statistically significant difference was found for the medium depth target (t=0.077,P=0.916).Conclusion In comparison with conventional US,IP system guided puncture is more accurate and the number of attempt and spent time is less .
Texto completo:
1
Base de datos:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Medical Ultrasound (Electronic Edition)
Año:
2013
Tipo del documento:
Article