Your browser doesn't support javascript.
loading
Determination of Norcantharidin using high performance liquid chromatography / 中国药理学通报
Article en Zh | WPRIM | ID: wpr-553973
Biblioteca responsable: WPRO
ABSTRACT
ABSTRACT AIM To determine Norcantharidin in its tables. METHODS A PHLC method was adopted, using Polaris C18 column(5?,4.6?250 mm) and UV detector at 211 nm wavelength. The mobile phase is consisted of water: methanol(85 : 15 V/V), adjust the pH to 3.1 with phosphoric acid. RESULT Excellent liner relationship was ob- tained from the range of 25 to 1 000 mg ? L-1. The minimal limit of Norcantharidin was 0.2 mg ? L-1. Recovery was 100.84% and RDS was 1.335%. COUCLUSION Practice suggested that this method was rapid, accuracy and suitable for Norcantharidin determining.
Palabras clave
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Pharmacological Bulletin Año: 1986 Tipo del documento: Article