The value of volume reaction evaluation through stroke volume variation combined with passive leg test for septic shock patients with autonomous breathing / 实用医学杂志
The Journal of Practical Medicine ; (24): 2084-2085, 2014.
Article en Zh | WPRIM | ID: wpr-453040
Biblioteca responsable: WPRO
ABSTRACT
Objective To evaluate the value of PLR-△SVV for the septic shock patients with autonomous breathing. Methods 60 patients were included in the study. Hemodynamic data of PICCO were collected before and after treatment. After rehydration, the group (△SV≥10%) was defined volume responder group, and then the predictive value of PLR-△SVV was analyzed. Results Compared with the nonresponders group, PLR-△SVV was increased significantly in response group[(10 ± 4)mL vs (14 ± 6)mL,P<0.05]. The ROC curve for PLR-△SVV were 0.881, and the sensitivity was 85.7%, the specificity was 92.0%. Conclusion PLR-△SVV can be used to predict fluid responsiveness for septic shock patients with spontaneously breathing.
Palabras clave
Texto completo: 1 Base de datos: WPRIM Tipo de estudio: Prognostic_studies Idioma: Zh Revista: The Journal of Practical Medicine Año: 2014 Tipo del documento: Article