Your browser doesn't support javascript.
loading
Dosimetric study of volumetric intensity-modulated arc therapy and fixed field intensity-modulated radiotherapy for cervix cancer / 中华放射肿瘤学杂志
Article en Zh | WPRIM | ID: wpr-430125
Biblioteca responsable: WPRO
ABSTRACT
Objective To compare the dosimetry characteristics of volumetric intensity-modulated arc therapy (VIMAT) and fixed field intensity-modulated radiation therapy (FF-IMRT) for cervix cancer.Methods CT images of 13 patients with cervix uteri cancer were transferred into Eclipse planning system.FF-IMRT and VIMAT plans were optimized on an Eclipse treatment planning system using beam data generated for Varian trilogy linear accelerator.Planning target volume (PTV) and organs at risk were evaluated with dose-volume histogram.To appraise the difference between the techniques,the paired t-test was applied.Results Compared with the FF-IMRT plans,PTV95% coverage of VIMAT plan group increased (t =9.84,P =0.000),PTV110% became lower (t =-3.72,P =0.003),Dmax decreased (t =-3.51,P=0.005),and CI became worser (t=5.39,P=0.000).PTV105%,Dmean,and HI had no difference (t =-0.02,-0.60,1.13,P =0.842,0.560,0.283).V30 of the bladder was reduced by about 10% (t =-4.99,P =0.000),and Dmean and Dmax were 1.4 Gy and 1.5 Gy lower respectively (t =-3.65,-18.03,P =0.004,0.000) ;V40 of the rectum was reduced by about 10% (t =-2.99,P =0.012),and Dmean and Dmax were reduced by 0.6 Gy,0.8 Gy respectively (t =-2.98,-4.05,P =0.013,0.002) ;V30,V40 and V50 of the small intestine were reduced by 16%,10% and 11% (t =-10.85,-4.74,-8.66,P =0.000,0.001,0.000),and Dmax was reduced by 0.8 Gy (t =-9.45,P =0.000) ; V30,V40 and V50 of the bone marrow were reduced by 26%,19% and 16% (t =-22.10,-10.19,-4.04,P =0.000,0.000,0.002),and Dmean reduced by 1.9 Gy (t =-16.21,P =0.000) ; D5 of the left and right femoral heads were reduced by 1.6 Gy and 2.7 Gy (t =-2.89,-6.22,P =0.015,0.000).Dmax of the caudate equine was reduced by 1.5 Gy (t=-4.80,P=0.001).V20,V30,V40 and V50 of the body were reduced by 18%,18%,4% and3%(t=-7.52,-11.75,-6.26,-6.94,P=0.000,0.000,0.000,0.000).Dmean and Dmax of the body decreased by 1.0 Gy and 0.4 Gy (t=-3.72,-3.51,P=0.000,0.005).Average machine unit (MU) decreased by 57% (t =-40.54,P =0.000).Conclusions cervical cancer Patients with VIMAT technology can get equivalent or superior dose distribution compared with the FF-IMRT technology.And VIMAT technology could reduce MU.But the efficacy needs further clinical evaluation
Palabras clave
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Radiation Oncology Año: 2012 Tipo del documento: Article
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Radiation Oncology Año: 2012 Tipo del documento: Article