Study on the weaning method of mechanical ventilation in the treatment of 51 patients with acute severe respiratory failure caused by organophosphate poisoning / 中国基层医药
Article en Zh | WPRIM | ID: wpr-425834
Biblioteca responsable: WPRO
ABSTRACT
ObjectiveTo explore the weaning method of mechanical ventilation in the treatment of acute severe respiratory failure caused by organophosphate poisoning.MethodsThe clinical features and weaning situation of 51 patients with acute severe respiratory failure caused by organophosphate poisoning by the treatment of mechanical ventilation were retrospectively analyzed.ResultsIn 51 cases,45 cases were cured,the survival rate was 88.2% and 6 cases died,the fatality rate 11.8%.Conclusion Early ventilator to rescue and choose opportunity for weaning could directly impact on the qualitv of life of patients,and improve outcomes,and reduce mortality.
Palabras clave
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Primary Medicine and Pharmacy Año: 2012 Tipo del documento: Article