Ultrasound puncture holder guided catheterization in internaljugular vein: report of 124 cases / 国际外科学杂志
International Journal of Surgery
; (12): 605-608, 2011.
Article
en Zh
| WPRIM
| ID: wpr-421511
Biblioteca responsable:
WPRO
ABSTRACT
ObjectiveOne hunred and twenty-four To probe into application value of ultrasound guided Catheterization in internal jugular vein. MethodsOne hundrel and twenty-four guided by ultrasound puncture holder, single-channel or three-channel catheter was embedded into jugular vein. ResultsThe catheter was inserted successfully by only one procedure in all the 124 patients. There was no complication. ConclusionsThe catheterization becomes safer, convenient and quickly with ultrasound puncture holder guidance, decreasing failure rate and complication of the procedure.
Texto completo:
1
Base de datos:
WPRIM
Idioma:
Zh
Revista:
International Journal of Surgery
Año:
2011
Tipo del documento:
Article