Optimal Anticoagulant Therapy after Mechanical Valve Replacement Reviewed in Terms of Activity of Coagulation and Fibrinolysis / 日本心臓血管外科学会雑誌
Article en Ja | WPRIM | ID: wpr-366935
Biblioteca responsable: WPRO
ABSTRACT
Patients with mechanical valve prosthesis must receive long-term oral anticoagulant therapy, thus it is important to set the optimal international normalized ratio of prothrombin time (PT-INR) that effectively prevented thromboembolic complications without excessive bleeding. In this study, anticoagulant therapy was evaluated in terms of the activity of coagulation and fibrinolysis in 137 patients after isolated mechanical valve replacement. With a lower target range of 1.5-2.0 for the PT-INR, thrombin antithrombin III complex (TAT) increased to more than 3.0ng/ml in 30 cases, and the activity of coagulation appeared to increase due to insufficient anticoagulant therapy. After the target range was raised to 2.0-2.5 in all cases, the PT-INR increased significantly from 1.63 to 2.25 (<i>p</i><0.01) and TAT decreased significantly from 7.58 to 2.81ng/ml (<i>p</i><0.01). This showed that activity of coagulation and fibrinolysis was suppressed by high intensity anticoagulation. It is necessary to review the individual activity of coagulation and fibrinolysis to determine the intensity of anticoagulation. We recommend 2.0-2.5 as the target range for the PT-INR.
Texto completo: 1 Base de datos: WPRIM Idioma: Ja Revista: Japanese Journal of Cardiovascular Surgery Año: 2004 Tipo del documento: Article