Your browser doesn't support javascript.
loading
One-Stage Repair for Infants with Complex Coarctation without Homologous Blood Transfusion / 日本心臓血管外科学会雑誌
Article en Ja | WPRIM | ID: wpr-366557
Biblioteca responsable: WPRO
ABSTRACT
We successfully performed one-stage definitive repair for 3 infants weighing 4.2, 6.1 and 5.2kg with complex coarctation without homologous blood transfusion. The priming volume of the bypass circuits was 195ml, and their lower hematocrit values during cardiopulmonary bypass were 15, 16 and 13%, respectively. In order to diminish the aortic cross clamp time, the aortic arch was repaired with the heart beating, using isolated cerebral and myocardial perfusion methods. The base excess in each patient decreased to -9.4, -8.0 and -4.9mEq/<i>l</i> during the rewarming phase, however, their postoperative hemodynamic and respiratory conditions were satisfactory. They have grown without any sequelae for at least 2 months.
Texto completo: 1 Base de datos: WPRIM Idioma: Ja Revista: Japanese Journal of Cardiovascular Surgery Año: 2000 Tipo del documento: Article