A Case of Paraplegia Following Endovascular Stent Repair of Descending Thoracic Aortic Aneurysm
Korean Circulation Journal
; : 160-163, 2011.
Article
en En
| WPRIM
| ID: wpr-224361
Biblioteca responsable:
WPRO
ABSTRACT
Paraplegia secondary to spinal cord infarction is a recognized complication of open thoracic and thoracoabdominal aortic aneurysm (TAA) repair. TAA is serious and unpredictable condition. Therefore, aortic repair requires thorough information on managing the potential complications will facilitate improve control the problem. We report the symptoms and management of paraplegia in a patient who underwent stent insertion as TAA.
Palabras clave
Texto completo:
1
Base de datos:
WPRIM
Asunto principal:
Paraplejía
/
Médula Espinal
/
Stents
/
Aneurisma de la Aorta Torácica
/
Aneurisma de la Aorta Abdominal
/
Isquemia de la Médula Espinal
/
Infarto