Study on the feasibility of the application of organ dose modulation technique of CT scanning for the eye / 中国医学装备
China Medical Equipment ; (12): 40-45, 2024.
Article en Zh | WPRIM | ID: wpr-1026442
Biblioteca responsable: WPRO
ABSTRACT
Objective:To study the feasibility and value of applying organ dose modulation technique in computed tomography(CT)scanning on eyes.Methods:A total of 330 patients who admitted to Beijing Friendship Hospital affiliated with Capital Medical University from August 2021 to August 2023 and underwent CT examination on eyes were selected.They were divided into modulation group,conventional group and low-dose group based on the control methods of tube current in scanning.The modulation group used organ dose modulation technique with intelligent automatic tube current of 70-150 mA,and the conventional dose group used a fixed tube current of 100 mA,and the low-dose group used a fixed tube current of 70 mA.The differences in radiation dose and CT imaging quality among 3 groups were compared.Results:The dose length product(DLP),volume CT dose index(CTDIvol)and effective dose(ED)of cross-sectional scan of the modulation group were respectively 62.37,12.83 and 0.143 mSv,which were significantly lower than 115.23,18.93 and 0.265mSv of conventional dose group,respectively,with statistically significant(F=2544.944,6009.596,2544.944,P<0.05).The DLP,CTDIvol and ED of coronary scan of the modulation group were 68.19,13.15 and 0.156,respectively,which were significantly lower than 122.41,19.20 and 0.282 mSv of the conventional dose group,respectively,with statistically significant(F=1232.413,3813.940,1232.413,P<0.05).The excellent rates of cross-sectional scans among the modulation group,conventional group and lower-dose group were respectively 98.83%,86.15%and 47.69%,and the difference among three groups was statistically significant(x2=53.908,P<0.05).The excellent rates of image qualities of the modulation group,conventional group and low-dose group were respectively 96.61%,80.70%and 48.28%,and the difference among three groups was statistically significant(x2=20.992,P<0.05).Conclusion:The application of organ dose modulation technique in CT scanning on eyes can significantly reduce radiation dose on patient under ensures imaging quality can meet diagnostic needs when undergoes cross-sectional and coronal scans,which has higher clinical feasibility and application value.
Palabras clave
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: China Medical Equipment Año: 2024 Tipo del documento: Article
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: China Medical Equipment Año: 2024 Tipo del documento: Article