Your browser doesn't support javascript.
loading
Evaluation for optimization effects of sperm floating plate / 临床检验杂志
Article en Zh | WPRIM | ID: wpr-1019095
Biblioteca responsable: WPRO
ABSTRACT
Objective To compare the difference between sperm floating plate and density gradient centrifugation combined with swim-up in human sperm preparation.Methods The semen samples were obtained from 50 infertile men in the clinic of Reproductive Medi-cine of Northwest Women's and Children's Hospital excluding azoospermia,severe oligoasthenozoospermia and semen volume less than 2 mL.After semen liquefaction,the differences of sperm concentration,total progressively motile sperm count(TMSC),percentages of progressively motile sperm and normal morphology sperm,recovery rate and DNA fragmentation index(DFI)were measured by both the methods of sperm floating plate and density gradient centrifugation combined with swim-up,and the results were compared.Results Compared with the pre-sorting samples,sperm concentrations[(16.08±13.39)x 106/mL,(8.88±8.06)x 106/mL vs(60.05± 27.21)×106/mL],TMSC[(7.41±6.14)×106,(3.98±3.57)×106vs(22.24±13.74)×106]and DFI[(2.20±3.44)%,(5.20± 10.79)%vs(26.38±13.92)%]in the sorting groups by sperm floating plate and density gradient centrifugation combined with swim-up were decreased significantly,and the percentages of progressive motile sperm[(91.67±4.75)%,(87.86±7.90)%vs(40.21± 16.83)%]and normal morphology sperm[(9.58±5.08)%,(7.72±4.01)%vs(3.58±2.06)%]were increased significantly.Com-pared with the density gradient centrifugation combined with swim-up,the results of sperm floating plate were higher in sperm concen-tration,percentages of progressively motile sperm and normal morphology sperm,TMSC and sperm recovery rate[(30.74±13.70)%vs(17.09±9.20)%],but DFI was lower,time-consuming was shorter[(32.38±1.01)min vs(60.08±2.06)min],and the difference between the two groups was statistically significant(P<0.05).Conclusion The sperm floating plate may have certain clinical applica-tion prospects in the future due to better parameters of sperm preparation than those of density gradient centrifugation combined with swim-up in simple operation and shorter time-consuming.
Palabras clave
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Clinical Laboratory Science Año: 2023 Tipo del documento: Article
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Chinese Journal of Clinical Laboratory Science Año: 2023 Tipo del documento: Article