Blood matching incompatibility caused by cold autoantibodies and IgG anti S antibody: a case report / 中国输血杂志
Chinese Journal of Blood Transfusion
; (12): 1165-1167, 2023.
Article
en Zh
| WPRIM
| ID: wpr-1003958
Biblioteca responsable:
WPRO
ABSTRACT
【Objective】 To analyze the serological characteristics of an anemia patient with cold autoantibodies and IgG anti S antibody. 【Methods】 Unexpected antibody screening was performed on screening cells, autologous cells and panel cells with patient serum in saline and anti human globulin card media at room temperature and 37 ℃, respectively. At the same time, the serum that destroying IgM antibodies and acid elution solution were respectively screened for unexpected antibodies in anti human globulin card media. The absorption-elution test was used to treat patients′ red blood cells and serum, and the unexpected antibody identification and cross matching were performed after excluding the interference of cold autoantibodies. 【Results】 Cold autoantibodies and IgG anti S antibody were found in the serum of this patient. 【Conclusion】 When a patient is found to have cold autoantibodies, it is necessary to screen the alloantibody, in order to avoid post transfusion immune reactions due to missed detection of alloantibody.
Texto completo:
1
Base de datos:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Blood Transfusion
Año:
2023
Tipo del documento:
Article