Este articulo es un Preprint
Los preprints son informes de investigación preliminares que no han sido certificados por revisión por pares. No deben considerarse para guiar la práctica clínica o los comportamientos relacionados con la salud y no deben publicarse en los medios como información establecida.
Los preprints publicados en línea permiten a los autores recibir comentarios rápidamente, y toda la comunidad científica puede evaluar de forma independiente el trabajo y responder adecuadamente. Estos comentarios se publican junto con los preprints para que cualquiera pueda leer y servir como una revisión pospublicación.
Diagnostic accuracy of Loop mediated isothermal amplification coupled to Nanopore sequencing for the detection of SARS-CoV-2 infection at scale in symptomatic and asymptomatic populations
Preprint
en En
| PREPRINT-MEDRXIV
| ID: ppmedrxiv-20247031
ABSTRACT
IntroductionRapid, high throughput diagnostics are a valuable tool, allowing the detection of SARS-CoV-2 in populations, in order to identify and isolate people with asymptomatic and symptomatic infections. Reagent shortages and restricted access to high throughput testing solutions have limited the effectiveness of conventional assays such as reverse transcriptase quantitative PCR (RT-qPCR), particularly throughout the first months of the COVID-19 pandemic. We investigated the use of LamPORE, where loop mediated isothermal amplification (LAMP) is coupled to nanopore sequencing technology, for the detection of SARS-CoV-2 in symptomatic and asymptomatic populations. MethodsIn an asymptomatic prospective cohort, for three weeks in September 2020 health care workers across four sites (Birmingham, Southampton, Basingstoke and Manchester) self-swabbed with nasopharyngeal swabs weekly and supplied a saliva specimen daily. These samples were tested for SARS-CoV-2 RNA using the Oxford Nanopore LamPORE system and a reference RT-qPCR assay on extracted sample RNA. A second retrospective cohort of 848 patients with influenza like illness from March 2020 - June 2020, were similarly tested from nasopharyngeal swabs. ResultsIn the asymptomatic cohort a total of 1200 participants supplied 23,427 samples (3,966 swab, 19,461 saliva) over a three-week period. The incidence of SARS-CoV-2 detection using LamPORE was 0.95%. Diagnostic sensitivity and specificity of LamPORE was >99.5% in both swab and saliva asymptomatic samples when compared to the reference RT-qPCR test. In the retrospective symptomatic cohort, the incidence was 13.4% and the sensitivity and specificity were 100%. ConclusionsLamPORE is a highly accurate methodology for the detection of SARS-CoV-2 in both symptomatic and asymptomatic population settings and can be used as an alternative to RT-qPCR.
cc_by
Texto completo:
1
Colección:
09-preprints
Base de datos:
PREPRINT-MEDRXIV
Tipo de estudio:
Cohort_studies
/
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
Idioma:
En
Año:
2020
Tipo del documento:
Preprint