Percutaneous retrieval of a central venous catheter sutured to the wall of the right atrium.
Cardiovasc Intervent Radiol
; 22(1): 79-80, 1999 Jan.
Article
en En
| MEDLINE
| ID: mdl-9929552
A transjugular central venous catheter was inadvertently sutured to the wall of the right atrium in a 63-year-old female during coronary bypass surgery. Using two nitinol Goose Neck snares via a transfemoral and a transjugular approach the catheter was severed into two pieces and retrieved percutaneously.