Percutaneous retrieval of a central venous catheter sutured to the wall of the right atrium.
Neuerburg, J M; Günther, R W; Chalabi, K; Hunter, D.
Afiliación
  • Neuerburg JM; Department of Diagnostic Radiology, University of Technology Aachen, Pauwelsstrasse 30, D-52057 Aachen, Germany.
Cardiovasc Intervent Radiol ; 22(1): 79-80, 1999 Jan.
Article en En | MEDLINE | ID: mdl-9929552
A transjugular central venous catheter was inadvertently sutured to the wall of the right atrium in a 63-year-old female during coronary bypass surgery. Using two nitinol Goose Neck snares via a transfemoral and a transjugular approach the catheter was severed into two pieces and retrieved percutaneously.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cateterismo Venoso Central / Cuerpos Extraños / Atrios Cardíacos Tipo de estudio: Etiology_studies Límite: Female / Humans / Middle aged Idioma: En Revista: Cardiovasc Intervent Radiol Año: 1999 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cateterismo Venoso Central / Cuerpos Extraños / Atrios Cardíacos Tipo de estudio: Etiology_studies Límite: Female / Humans / Middle aged Idioma: En Revista: Cardiovasc Intervent Radiol Año: 1999 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Estados Unidos