Your browser doesn't support javascript.
loading
IgM and IgG antibodies to hepatitis E virus (HEV) detected by an enzyme immunoassay based on an HEV-specific artificial recombinant mosaic protein.
Favorov, M O; Khudyakov, Y E; Mast, E E; Yashina, T L; Shapiro, C N; Khudyakova, N S; Jue, D L; Onischenko, G G; Margolis, H S; Fields, H A.
Afiliación
  • Favorov MO; Hepatitis Branch, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia 30333, USA.
J Med Virol ; 50(1): 50-8, 1996 Sep.
Article en En | MEDLINE | ID: mdl-8890041
To develop an enzyme immunoassay (EIA) for IgM antibody to hepatitis E virus (HEV) (IgM anti-HEV) and IgG antibody to HEV (IgG anti-HEV), a synthetic gene encoding several liner immunodominant antigenic epitopes from HEV structural proteins was assembled as a chimeric recombinant mosaic protein (Mpr) with glutathione S-transferase and used as an immunodiagnostic target. In addition, a neutralization confirmation test was developed using individual synthetic peptides. Among 614 patients with acute hepatitis from 10 geographically distinct outbreaks, IgG anti-HEV was found in 546 (88.9%), with a range of 77-100% depending on the outbreak. Of 130 patients tested for IgM anti-HEV, 126 (96.9%) were positive. Among patients tested within 4 months of onset of jaundice, 37/37 (100%) were IgG anti-HEV positive. For patients from whom sera were collected 1-16 days after onset of jaundice, the geometric mean IgG titer (GMT) was 1:47,000; the GMT increased to 1:70,710 30-40 days after onset of jaundice and decreased to 1:1,778 3-4 months after the onset of jaundice. For patients tested 6-8 months after onset of jaundice, 11/12 (92%) were IgG anti-HEV positive, and the GMT was 1:2,908. IgM anti-HEV was detected in 43/43 (100%) sera collected 1-40 days after onset of jaundice, and the GMT for IgM anti-HEV was 1:10,000 at that time. For sera collected 3-4 and 6-12 months after onset of jaundice, 7/14 (50%) and 5/12 (40%) respectively, were IgM anti-HEV positive. In conclusion, an artificial mosaic protein composed of linear antigenic epitopes from open reading frame 2 (ORF2) and ORF3 of HEV has been successfully applied to the development of a sensitive and specific EIA for the detection of IgG and IgM anti-HEV activity. These assays were used for the verification of HEV infection in outbreak settings and for the diagnosis of HEV infection in sporadic cases.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Anticuerpos Antihepatitis / Técnicas para Inmunoenzimas / Virus de la Hepatitis E / Hepatitis E / Antígenos de la Hepatitis Límite: Humans Idioma: En Revista: J Med Virol Año: 1996 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Anticuerpos Antihepatitis / Técnicas para Inmunoenzimas / Virus de la Hepatitis E / Hepatitis E / Antígenos de la Hepatitis Límite: Humans Idioma: En Revista: J Med Virol Año: 1996 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos