Determination of acrylamide in rat serum and sciatic nerve by gas chromatography-electron-capture detection.
J Chromatogr
; 619(2): 223-34, 1993 Sep 22.
Article
en En
| MEDLINE
| ID: mdl-8263094
A modified method for the derivatization and determination of acrylamide as 2-bromopropenamide by gas chromatography-electron-capture detection was developed and applied to serum and sciatic nerve from rats. The method was accurate and precise over the calibration range 2.24-7.47 micrograms/ml in serum diluted 1:125 and 4-122 micrograms/g in sciatic nerve homogenate (5 mg/ml). limits of detection were estimated to be 1200 ng/ml in undiluted serum and 3 micrograms/g in intact sciatic nerve. The use of less dilute samples to allow for lower limits of detection appears feasible. The time-course of acrylamide in serum and sciatic nerve was studied after acute dosing and indicated elimination half-lives of 1.8 and 2.0 h for serum and sciatic nerve, respectively. A dose-effect relationship was established for each matrix after acute dosing and the measured acrylamide concentrations in serum (microgram/ml) were approximately the same as in sciatic nerve (microgram/g).
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Nervio Ciático
/
Acrilamidas
Tipo de estudio:
Diagnostic_studies
Límite:
Animals
Idioma:
En
Revista:
J Chromatogr
Año:
1993
Tipo del documento:
Article
Pais de publicación:
Países Bajos