Toric intraocular lenses: correcting astigmatism while controlling axis shift.
Shimizu, K; Misawa, A; Suzuki, Y.
Afiliación
  • Shimizu K; Department of Ophthalmology, Musashino Red Cross Hospital, Tokyo, Japan.
J Cataract Refract Surg ; 20(5): 523-6, 1994 Sep.
Article en En | MEDLINE | ID: mdl-7996408
We evaluated the efficacy of toric intraocular lenses (IOLs) implanted in the eyes of 47 patients who had preoperative against-the -rule astigmatism. The lenses, which had a cylinder power of 2.00 diopters (D) (n = 26) or 3.00 D (n = 21), were implanted through a 5.7 mm incision after cataract extraction by phacoemulsification. Best corrected visual acuity three months postoperatively was 20/25 or better in 77% of eyes. The 3.00 D IOLs resulted in better correction than the 2.00 D IOLs when the axis shift of the lens was less than 30 degrees. A negative effect occurred in some eyes in which the lens axis rotated more than 30 degrees. The maximum acceptable axis shift seems to be less than 30 degrees.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Astigmatismo / Lentes Intraoculares Límite: Aged / Humans Idioma: En Revista: J Cataract Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 1994 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Astigmatismo / Lentes Intraoculares Límite: Aged / Humans Idioma: En Revista: J Cataract Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 1994 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos