Effect of bentonites on fluorometric selenium determination.
J Assoc Off Anal Chem ; 64(5): 1088-91, 1981 Sep.
Article en En | MEDLINE | ID: mdl-7287605
Bentonites in feeds cause error in the analysis for Se by the AOAC (3.097-3.101) fluorometric method for Se in plants. The error apparently results from the binding of the piazselenol by insoluble residue from the bentonite. This effect is avoided by diluting digests to volume after reduction with HCl, centrifuging or allowing to stand, and analyzing a portion of the clear supernatant liquid. Insoluble residues present after digestion of plant materials do not appear to cause a similar error.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Plantas / Selenio / Bentonita / Alimentación Animal Idioma: En Revista: J Assoc Off Anal Chem Año: 1981 Tipo del documento: Article Pais de publicación: Estados Unidos