Patency rate of bifurcated aortic grafts: comparative analysis of woven versus knitted prostheses in the same patient.
Ann Thorac Surg
; 40(2): 172-4, 1985 Aug.
Article
en En
| MEDLINE
| ID: mdl-4026448
To investigate the difference in patency rate between woven and knitted aortofemoral or aortoiliac prosthetic grafts, a special vascular prosthesis was manufactured with one limb of the graft knitted and the other, woven. The prosthesis was implanted in 143 consecutive patients with occlusive aortoiliac arteriosclerotic disease or aneurysms. Detailed statistical analysis failed to reveal any difference in the patency rate between the woven and knitted limbs of the grafts during an observation period ranging from one month to two years.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Aorta Abdominal
/
Prótesis Vascular
/
Oclusión de Injerto Vascular
Tipo de estudio:
Diagnostic_studies
/
Evaluation_studies
Límite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Ann Thorac Surg
Año:
1985
Tipo del documento:
Article
Pais de publicación:
Países Bajos