Patency rate of bifurcated aortic grafts: comparative analysis of woven versus knitted prostheses in the same patient.
Ann Thorac Surg ; 40(2): 172-4, 1985 Aug.
Article en En | MEDLINE | ID: mdl-4026448
To investigate the difference in patency rate between woven and knitted aortofemoral or aortoiliac prosthetic grafts, a special vascular prosthesis was manufactured with one limb of the graft knitted and the other, woven. The prosthesis was implanted in 143 consecutive patients with occlusive aortoiliac arteriosclerotic disease or aneurysms. Detailed statistical analysis failed to reveal any difference in the patency rate between the woven and knitted limbs of the grafts during an observation period ranging from one month to two years.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta Abdominal / Prótesis Vascular / Oclusión de Injerto Vascular Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Surg Año: 1985 Tipo del documento: Article Pais de publicación: Países Bajos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Aorta Abdominal / Prótesis Vascular / Oclusión de Injerto Vascular Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Surg Año: 1985 Tipo del documento: Article Pais de publicación: Países Bajos