Your browser doesn't support javascript.
loading
Comparison of Hemodynamic Performance, Three-Dimensional Flow Fields, and Turbulence Levels for Three Different Heart Valves at Three Different Hemodynamic Conditions.
Ferrari, Lorenzo; Obrist, Dominik.
Afiliación
  • Ferrari L; ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland. lorenzo.ferrari@unibe.ch.
  • Obrist D; ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Ann Biomed Eng ; 2024 Sep 17.
Article en En | MEDLINE | ID: mdl-39287910
ABSTRACT
The hemodynamic performance of different prosthetic heart valves is difficult to compare among studies due to a variety of test conditions and experimental techniques. Existing studies are typically limited to one family of valves (biological or mechanical) and testing conditions of 5l/min and often lack sufficient spatial resolution. To address these limitations, a pulse duplicator with a multi-view imaging system (Tomo-PIV) was employed to investigate the three-dimensional flow field in the aortic root of three different valves a tri-leaflet mechanical heart valve (TRIFLO, Novostia), a bi-leaflet mechanical heart valve (On-X, Artivion), and a biological heart valve (Perimount, Edwards Lifesciences). The valves were tested at low (3 l/min), normal (5 l/min), and elevated (7 l/min) cardiac output ( C O ) under hypotensive (40/60mmHg), normotensive (80/120mmHg), and moderate hypertensive (105/170mmHg) pressure conditions, respectively. Compared to the Perimount, peak mean velocity was - 33%, - 24%, - 18% for the TRIFLO and - 32%, - 20%, - 11% for the On-X at low, moderate, and elevated CO , respectively. Corresponding peak TKE values decreased by - 66%, - 57%, - 44% (TRIFLO) and - 60%, - 50%, - 36% (On-X). At low CO , EOA was lower for Perimount (1.07cm2) than for TRIFLO (1.47cm2) and On-X (1.52cm2), while it increased for elevated CO to 2.75cm2 (TRIFLO) and 2.16cm2 (Perimount and On-X). For all valves, increasing CO led to increased flow velocities, higher E O A , and higher levels of turbulence, and the spatial influence of the valve on the flow field in the ascending aorta was extended. TKE peaked closer to the STJ than for TRIFLO and Perimount.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ann Biomed Eng Año: 2024 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ann Biomed Eng Año: 2024 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Estados Unidos