Your browser doesn't support javascript.
loading
Development of a bioluminescent immunoassay based on Fc-specific conjugated antibody-nanoluciferase immunoreagents for determining aflatoxin B1.
Du, Yue; Yang, Hong-Ming; Zhang, Yu-Min; Ma, Lan; Gong, Xiao-Ming; Tang, Jin-Bao.
Afiliación
  • Du Y; Department of Biochemical Drugs, School of Pharmacy, Shandong Second Medical University, Weifang 261053, Shandong Province, China.
  • Yang HM; Department of Biochemical Drugs, School of Pharmacy, Shandong Second Medical University, Weifang 261053, Shandong Province, China.
  • Zhang YM; Department of Biochemical Drugs, School of Pharmacy, Shandong Second Medical University, Weifang 261053, Shandong Province, China.
  • Ma L; Department of Biochemical Drugs, School of Pharmacy, Shandong Second Medical University, Weifang 261053, Shandong Province, China.
  • Gong XM; Weifang Customs, Weifang 261031, Shandong Province, China.
  • Tang JB; Department of Biochemical Drugs, School of Pharmacy, Shandong Second Medical University, Weifang 261053, Shandong Province, China. Electronic address: tangjb@sdsmu.edu.cn.
Food Chem ; 463(Pt 2): 141220, 2024 Sep 10.
Article en En | MEDLINE | ID: mdl-39265299
ABSTRACT
Aflatoxin B1 (AFB1) is a potent carcinogen, and is among the most hazardous mycotoxins in agricultural products. Therefore, the development of sensitive and convenient detection methods for AFB1 is significant for food safety against mycotoxins. Herein, a bioluminescent enzyme immunoassay (BLEIA) was developed for ultrasensitive detection of AFB1, based on the novel Fc-specific antibody-nanoluciferase (Ab-Nluc) conjugates which were fabricated using an IgG-binding protein-assisted photo-conjugation strategy. In indirect competitive immunoassay format, the proposed BLEIA exhibited the detection limit of 0.0232 ng mL-1, which was 37.4-fold lower than that obtained using the classical enzyme-linked immunosorbent assay (ELISA) based on Ab-horseradish peroxidase (Ab-HRP) chemical conjugates (0.868 ng mL-1). Meanwhile, the BLEIA exhibited high accuracy and precision. Thus, the proposed Fc-specific Ab-Nluc conjugates-based BLEIA provides an ultrasensitive and reliable method for detecting toxins and has potential for use in food safety monitoring.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Food Chem Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Food Chem Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Reino Unido