Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China.
Sun, Donglei; Tang, Li; Long, Keyan; Sun, Weilian; Zhang, Zunzhen.
Afiliación
  • Sun D; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
  • Tang L; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
  • Long K; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
  • Sun W; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
  • Zhang Z; West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.
Front Public Health ; 12: 1429626, 2024.
Article en En | MEDLINE | ID: mdl-39206014
ABSTRACT

Introduction:

Air flow driven by air-conditioner has a significant impact on the indoor environment, however, the bacterial contamination conditions in the different parts of air-conditioners have not been fully elucidated.

Methods:

In this study, we assessed the bacterial pollution in the four parts, including air outlet, filter net, cooling fin and water sink, of ten household air-conditioners quantitatively and qualitatively from Chengdu, southwestern China.

Results:

The microbial cultivation results showed the large total bacterial counts of 5042.0, 9127.6, 6595.1, and 12296.2 CFU/cm2 in air outlet, filter net, cooling fin, and water sink. Furthermore, the sequencing data showed that these four parts displayed different bacterial characteristics. At the level of genus, Caproiciproducens and Acidipropionibacterium were predominant in air outlet. Bacillus, Acinetobacter, Paracoccus, and Corynebacterium were detected as the characteristic bacteria in filter net. For cooling fin, Rhodococcus, Achromobacter, and Nocardioides were the dominant bacteria. The genera of Methylobacterium-Methylorubrum, Brevibacterium, Stenotrophomonas, and Psychrobacter were identified as the bioindicators in water sink. The bioinformatic analysis on the sequencing data illustrated that the bacteria from air-conditioners were associated with metabolic disturbance.

Discussion:

This study reveals the distinct bacterial compositions in the different parts of air-conditioner, and provides new clues for the non-negligible bacterial pollution in this common appliance from Chinese households.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bacterias / Contaminación del Aire Interior / Aire Acondicionado / Microbiología del Aire Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Front Public Health Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bacterias / Contaminación del Aire Interior / Aire Acondicionado / Microbiología del Aire Límite: Humans País/Región como asunto: Asia Idioma: En Revista: Front Public Health Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza