Distribution and propagation of stress and strain in cube honeycombs as trabecular bone substitutes: Finite element model analysis.
Wang, Guangxin; Liu, Jiaqi; Lian, Tingting; Sun, Yanyan; Chen, Xuewen; Todo, Mitsugu; Osaka, Akiyoshi.
Afiliación
  • Wang G; School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang, Henan Province, 471023, PR China. Electronic address: wgx58@126.com.
  • Liu J; School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang, Henan Province, 471023, PR China.
  • Lian T; School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang, Henan Province, 471023, PR China.
  • Sun Y; School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang, Henan Province, 471023, PR China.
  • Chen X; School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang, Henan Province, 471023, PR China.
  • Todo M; Research Institute for Applied Mechanics, Kyushu University, Kasuga, 816-8580, Japan.
  • Osaka A; School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang, Henan Province, 471023, PR China; Faculty of Engineering, Okayama University, Tsushima, Okayama, 700-8530, Japan. Electronic address: akiosaka@okayama-u.ac.jp.
J Mech Behav Biomed Mater ; 159: 106647, 2024 Nov.
Article en En | MEDLINE | ID: mdl-39178822
ABSTRACT
For designing trabecular (Tb) bone substitutes suffering from osteoporosis, finite element model (FEM) simulations were conducted on honeycombs (HCs) of 8 × 8 × 1 (2D) and 8 × 8 × 8 (3D) assemblies of cube cellular units consisting of 0.9 mm long Nylon® 66 (PA, Young's modulus E 2.83 GPa) and polyethylene (PE, E 1.1 GPa) right square prisms. Osteoporotic damage to the Tb bone was simulated by removing the inner vertical struts (pillars; the number of removed pillars Δn ≤ 300) and by thinning the strut (thickness, d 0.4-0.1 mm), while the six facade lattices were kept flawless. Uniform and uniaxial compressive loads on the HCs induced elastic deformation of the struts. The pillars held almost all the load, while the horizontal struts (beams) shared little. E for PA 3D HCs of all d smoothly decreased with Δn. PA 3D HCs of 0.2 mm struts deserved to be the substitutes for Tb bone, while PE 3D HCs of 0.05 mm struts were only for the Tb bone of the poorest bone quality. For the PA 3D HCs, the maximum von Mises stress (σM) first rapidly increased with Δn and showed a break at Δñ50, then gradually approached the yield stress of PA (50 MPa). Moreover, small portions of the stress were transferred from the façade pillars to the adjacent inner beams, especially those near the lost-pillar sites, denoted as X defects. The floor beams of thinner struts associated with the X-defects were lifted, and similar lifting effects in smaller amounts were propagated to the other floors. The 3DHCs of the thicker struts showed no such flexural deformations. The concept of force percolation through the remaining struts was proposed to interpret those mechanical behaviors of the HCs.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estrés Mecánico / Ensayo de Materiales / Sustitutos de Huesos / Análisis de Elementos Finitos Idioma: En Revista: J Mech Behav Biomed Mater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Estrés Mecánico / Ensayo de Materiales / Sustitutos de Huesos / Análisis de Elementos Finitos Idioma: En Revista: J Mech Behav Biomed Mater Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article Pais de publicación: Países Bajos