Your browser doesn't support javascript.
loading
Goniometry and fleximetry measurements to assess cervical range of motion in individuals with chronic neck pain: a validity and reliability study.
Araujo, Gabriel Gardhel Costa; Pontes-Silva, André; Leal, Plínio da Cunha; Gomes, Bruno Sousa; Reis, Maisa Lopes; de Mello Pereira Lima, Sâmira Kennia; Fidelis-de-Paula-Gomes, Cid André; Dibai-Filho, Almir Vieira.
Afiliación
  • Araujo GGC; Postgraduate Program in Physical Education, Department of Physical Education, Universidade Federal do Maranhão, São Luís, Maranhão, Brazil.
  • Pontes-Silva A; Instituto Center Fisio Inovare, São Luís, Maranhão, Brazil.
  • Leal PDC; Postgraduate Program in Physical Therapy, Department of Physical Therapy, Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil. contato.andrepsilva@gmail.com.
  • Gomes BS; Postgraduate Program in Physical Education, Department of Physical Education, Universidade Federal do Maranhão, São Luís, Maranhão, Brazil.
  • Reis ML; Postgraduate Program in Adult Health, Universidade Federal Do Maranhão, São Luís, Maranhão, Brazil.
  • de Mello Pereira Lima SK; Instituto Center Fisio Inovare, São Luís, Maranhão, Brazil.
  • Fidelis-de-Paula-Gomes CA; Instituto Center Fisio Inovare, São Luís, Maranhão, Brazil.
  • Dibai-Filho AV; Instituto Center Fisio Inovare, São Luís, Maranhão, Brazil.
BMC Musculoskelet Disord ; 25(1): 651, 2024 Aug 19.
Article en En | MEDLINE | ID: mdl-39160504
ABSTRACT

PURPOSE:

To assess the test-retest and inter-rater reliability of goniometry and fleximetry in measuring cervical range of motion in individuals with chronic neck pain.

METHODS:

A reliability study. Thirty individuals with chronic neck pain were selected. Cervical range of motion was measured by goniometry and fleximetry at two time points 7 days apart. To characterize the sample, we used the numerical pain rating scale, Pain-Related Catastrophizing Thoughts Scale, and Neck Disability Index. Intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change (MDC) were calculated. Correlations between goniometry and fleximetry measurements were performed using Spearman's correlation coefficient (rho).

RESULTS:

For goniometry, we found excellent test-retest reliability (ICC ≥ 0.986, SEM ≤ 1.89%, MDC ≤ 5.23%) and inter-rater reliability (ICC ≥ 0.947, SEM ≤ 3.91%, MDC ≤ 10.84%). Similarly, we found excellent test-retest reliability (ICC ≥ 0.969, SEM ≤ 2.71%, MDC ≤ 7.52%) and inter-rater reliability (ICC ≥ 0.981, SEM ≤ 1.88%, MDC ≤ 5.20%) for fleximetry. Finally, we observed a strong correlation between the goniometry and the fleximetry for all cervical movements (rho ≥ 0.993).

CONCLUSION:

Goniometry and fleximetry measurements are reliable for assessing cervical range of motion in individuals with chronic neck pain.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vértebras Cervicales / Rango del Movimiento Articular / Dolor de Cuello / Artrometría Articular / Dolor Crónico Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Vértebras Cervicales / Rango del Movimiento Articular / Dolor de Cuello / Artrometría Articular / Dolor Crónico Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Musculoskelet Disord Asunto de la revista: FISIOLOGIA / ORTOPEDIA Año: 2024 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Reino Unido