Comparative study of axial displacement in digital and conventional implant prosthetic components.
Back, Seungwon; Kim, Sunjai; Park, Jaehan; Pyo, Se-Wook; Chang, Jae-Seung.
Afiliación
  • Back S; Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Korea.
  • Kim S; Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Korea.
  • Park J; Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
  • Pyo SW; Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Korea.
  • Chang JS; Department of Prosthodontics, Gangnam Severance Dental Hospital, Yonsei University College of Dentistry, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Korea. JSCHANG@yuhs.ac.
Sci Rep ; 14(1): 19185, 2024 08 19.
Article en En | MEDLINE | ID: mdl-39160217
ABSTRACT
Axial displacement of prosthetic components is a major concern in implant dentistry, particularly during screw tightening. However, implant manufacturers provide different recommended torques for tightening implant prosthetic components, which can lead to errors in prosthesis fit before and after impression making. Implant-abutment connection angle or abutment geometries can affect axial displacement. This study aimed to compare the axial displacement between conventional and digital components based on the tightening torque and differences in the implant-abutment connection angles and geometries. The results showed that scan bodies with different implant-abutment connection geometries exhibited smaller axial displacement with increasing tightening torque than other prosthetic components. Except for the scan bodies, there was no difference in the axial displacement of prosthetic components when tightened with the same torque. However, regardless of the use of digital or conventional method of impression making, the axial displacement between the impression making component and the abutment when tightened to the recommended torques were significantly different. In addition, axial displacement was affected by the internal connection angle. The results of this study indicate that the tightening torque and geometry of prosthetic components should be considered to prevent possible misfits which can occur before and after impression making.