Your browser doesn't support javascript.
loading
Agreement between an automated video-based system and tethered system to measure instantaneous swimming velocity.
Scott, Michelle; Elsworthy, Nathan; Brackley, Victoria; Elipot, Marc; Kean, Crystal O.
Afiliación
  • Scott M; School of Health, Medical and Applied Sciences, Central Queensland University, Mackay, Queensland, Australia.
  • Elsworthy N; School of Health, Medical and Applied Sciences, Central Queensland University, Mackay, Queensland, Australia.
  • Brackley V; Victorian Institute of Sport, Melbourne Victoria, Australia.
  • Elipot M; Swimming Insight, Swimming Australia, Canberra, Australian Capital Territory, Australia.
  • Kean CO; School of Health, Medical and Applied Sciences, Central Queensland University, Mackay, Queensland, Australia.
Sports Biomech ; : 1-13, 2024 Aug 15.
Article en En | MEDLINE | ID: mdl-39145738
ABSTRACT
Successful performance in competitive swimming requires a swimmer to maximise propulsion and minimise drag, which can be assessed using instantaneous swimming velocity. Many systems exist to quantify velocity, and therefore, it is important to understand the agreement between systems. This study examined the agreement between an automated video-based system and a tethered system to measure instantaneous velocity. Twenty-two competitive swimmers (state level or higher) completed 25 m of each stroke at maximal intensity. The tethered speedometer was attached to the swimmer's waist, while videos of each trial were recorded. The swimmer's head was then automatically tracked using proprietary software, and instantaneous velocity was determined from each system. Bland-Altman plots showed good agreement between the two systems in backstroke (95% Limits of Agreement (LOA) -0.24-0.26 m.s-1) and freestyle (95% LOA -0.36-0.38 m.s-1) but poorer agreement in butterfly (95% LOA -0.51-0.53 m.s-1) and breaststroke (95% LOA -0.88-0.92 m.s-1). The root mean square error was higher in butterfly (0.27 m.s-1) and breaststroke (0.46 m.s-1) compared to backstroke (0.13 m.s-1) and freestyle (0.19 m.s-1). Results demonstrated that the two systems are comparable for measuring instantaneous swimming velocity; however, larger discrepancies are evident for butterfly and breaststroke.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sports Biomech Asunto de la revista: MEDICINA ESPORTIVA Año: 2024 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sports Biomech Asunto de la revista: MEDICINA ESPORTIVA Año: 2024 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido