Your browser doesn't support javascript.
loading
Role of radiation re-absorption in the thermal helium beam diagnostic.
Ugoletti, M; Agostini, M; La Matina, M; Scarin, P; Wang, Y; Wüthrich, C; Theiler, C; Andrebe, Y; Griener, M; Zuin, M.
Afiliación
  • Ugoletti M; ISTP-CNR, Institute for Plasma Science and Technology, Corso Stati Uniti 4, 35127 Padova, Italy.
  • Agostini M; ISTP-CNR, Institute for Plasma Science and Technology, Corso Stati Uniti 4, 35127 Padova, Italy.
  • La Matina M; Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova, Italy.
  • Scarin P; Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova, Italy.
  • Wang Y; Università degli Studi di Padova, Via 8 Febbraio 1848, 2, 35122 Padova, Italy.
  • Wüthrich C; Consorzio RFX (CNR, ENEA, INFN, UNIPD, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova, Italy.
  • Theiler C; EPFL, Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
  • Andrebe Y; EPFL, Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
  • Griener M; EPFL, Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
  • Zuin M; EPFL, Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Article en En | MEDLINE | ID: mdl-39140815
ABSTRACT
The Thermal Helium Beam (THB) is a diagnostic for simultaneously measuring the electron temperature and density profiles of the plasma edge and scrape off layer (SOL). It exploits the line ratio technique of selected He line intensities, emitted by He gas puffed inside the plasma, to locally estimate the plasma properties through a dedicated collisional radiative model (CRM). Standard THB diagnostics used in nuclear fusion devices measure three HeI emission lines 667.8, 706.5, and 728.1 nm. For the RFP experiment RFX-mod2, a new THB is designed and tested for the first time at the TCV tokamak. It acquires an additional emission line at 501.6 nm, which is exploited to estimate the radiation re-absorption, which is not negligible in regions of large neutral He densities (leading to high re-absorption) and simultaneously low electron density and temperature (lack of other excitation channels). It affects the measurements most strongly at the far SOL, while the significance of re-absorption decreases as it approaches the separatrix. In this paper, plasma density and temperature profiles of the plasma edge at the outboard midplane of TCV, measured with this newly designed THB, are presented. For the first time, the effect of radiation re-absorption on the estimation of electron temperature and density profiles is experimentally measured in a tokamak using the 501 nm line emission intensity. Different CRMs are compared with and without radiation re-absorption, showing good agreement when re-absorption is included and demonstrating how it plays an important role in the far SOL, as expected.