Your browser doesn't support javascript.
loading
Continuous Temperature Telemonitoring of Patients with COVID-19 and Other Infectious Diseases Treated in Hospital-at-Home: Viture® System Validation.
Sesma-Sánchez, Laura; Ruiz-Castellano, María; Romero-Roldán, Ainara; Álvarez-García, Laura; Morrás-Gómez, Marta; Tabar-Liberal, Idoia; Pulido-Fontes, Marta; Salmón-García, Belén.
Afiliación
  • Sesma-Sánchez L; Vitio® Medical SL., 31192 Tajonar, Navarra, Spain.
  • Ruiz-Castellano M; Hospital at Home Unit, Navarra University Hospital (HUN), 31008 Pamplona, Navarra, Spain.
  • Romero-Roldán A; Navarrabiomed, 31008 Pamplona, Navarra, Spain.
  • Álvarez-García L; Hospital at Home Unit, Navarra University Hospital (HUN), 31008 Pamplona, Navarra, Spain.
  • Morrás-Gómez M; Hospital at Home Unit, Navarra University Hospital (HUN), 31008 Pamplona, Navarra, Spain.
  • Tabar-Liberal I; Hospital at Home Unit, Navarra University Hospital (HUN), 31008 Pamplona, Navarra, Spain.
  • Pulido-Fontes M; Hospital at Home Unit, Navarra University Hospital (HUN), 31008 Pamplona, Navarra, Spain.
  • Salmón-García B; Hospital at Home Unit, Navarra University Hospital (HUN), 31008 Pamplona, Navarra, Spain.
Sensors (Basel) ; 24(15)2024 Aug 03.
Article en En | MEDLINE | ID: mdl-39124073
ABSTRACT
Body temperature must be monitored in patients receiving Hospital-at-Home (HaH) care for COVID-19 and other infectious diseases. Continuous temperature telemonitoring (CTT) detects fever and patient deterioration early, facilitating decision-making. We performed a validation clinical study assessing the safety, comfort, and impact on healthcare practice of Viture®, a CTT system, compared with a standard digital axillary thermometer in 208 patients with COVID-19 and other infectious diseases treated in HaH at the Navarra University Hospital (HUN). Overall, 3258 pairs of measurements showed a clinical bias of -0.02 °C with limits of agreement of -0.96/+0.92 °C, a 95% acceptance rate, and a mean absolute deviation of 0.36 (SD 0.30) °C. Viture® detected 3 times more febrile episodes and revealed fever in 50% more patients compared with spot measurements. Febrile episodes were detected 7.23 h (mean) earlier and modified the diagnostic and/or therapeutic approach in 43.2% of patients. Viture® was validated for use in a clinical setting and was more effective in detecting febrile episodes than conventional methods.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Temperatura Corporal / Fiebre / SARS-CoV-2 / COVID-19 Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: España Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Temperatura Corporal / Fiebre / SARS-CoV-2 / COVID-19 Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: España Pais de publicación: Suiza