Your browser doesn't support javascript.
loading
A SSA-based CFFOPID drop deloaded tidal turbine controller using HVDC-link.
Arya, Yogendra; Singh, Kavita.
Afiliación
  • Arya Y; J.C. Bose University of Science and Technology, YMCA, Haryana 121006, India. Electronic address: yarya@jcboseust.ac.in.
  • Singh K; Jamia Millia Islamia (A Central University), New Delhi 110025, India. Electronic address: kavitasingh.jamia@gmail.com.
ISA Trans ; 153: 306-321, 2024 Oct.
Article en En | MEDLINE | ID: mdl-39112127
ABSTRACT
In contemporary scenario, electric power companies have observed upsurge in penetration level of tidal power plants (TPPs) in the traditional electric power system framework. However, the tidal turbines offer less frequency assistance due to their lesser rotor mass. Hence, TPPs may be collaborated with conventional units like diesel engine generator (DEG) to confirm system frequency stability in multi-area micro-grid system. The DEG comprises of primary and proportional integral derivative (PID) secondary frequency controls. However, in TPPs, to advance the system frequency regulation, deloading control approach is suggested and a cascade fuzzy fractional order PID-ID with derivative filter (CFFOPID-IDF) droop controller is suggested in place of the conventional non-cascade controller droop in the deloaded region. The suggested controller gains are fetched exploiting Salps swarm algorithm. For further enhancement of the dynamic responses, a precise high voltage direct current (AHVDC) link with the inertia emulation-based control (INEC) scheme is adopted, which allows the utilization of the gathered energy from the capacitance of the HVDC interface for frequency regulation. It provides better results compared to conventional AC tie line interface having less undershoot (34 %/20.63 %/43.75 %) and settling time (20.45 %/59.09 %/16.83 %) for variation in area-1 frequency/area-2 frequency/tie line power, respectively. The recommended control scheme is evidenced superior over numerous existing control techniques and provides least cost function in contrast to other control techniques. Additionally, it offers a highly stable performance under variable load conditions.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ISA Trans Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: ISA Trans Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos