Sedaconda ACD-S for Sedation with Volatile Anaesthetics in Intensive Care: A NICE Medical Technologies Guidance.
Appl Health Econ Health Policy
; 22(6): 805-813, 2024 Nov.
Article
en En
| MEDLINE
| ID: mdl-39060904
ABSTRACT
Intensive care unit (ICU) patients receive highly complex care and often require sedation as part of their management. ICU sedation has traditionally been delivered using intravenous (IV) agents due to the impractical use of anaesthetic machines in this setting, which are used to deliver volatile sedation. Sedaconda anaesthetic conserving device (ACD)-S (previously known as AnaConDa-S) is a device which allows for the delivery of volatile sedation via the majority of mechanical ventilators by being inserted in the breathing circuit where the heat and moisture exchanger is normally placed. The National Institute of Health and Care Excellence (NICE), as part of the Medical Technologies Evaluation Programme, considered the potential benefits of using Sedaconda ACD-S compared to standard IV sedation in ICU patients. Here we describe the evidence evaluation undertaken by NICE on this technology, supported by CEDAR. CEDAR considered the evidence present in 21 publications that compared the clinical outcomes of patients receiving Sedaconda ACD-S-delivered sedation and IV sedation, and critiqued the economic model provided by the manufacturer. Clinical expert input during the evaluation process was used extensively to ensure that the relevant clinical evidence was captured and that the economic model was suitable for the UK setting. Due to the uncertainty of the evidence, sensitivity analysis was carried out on the key economic inputs to ensure the reliability of the results. Economic modelling has shown that Sedaconda ACD-S-delivered isoflurane sedation is cost saving on a 30-day horizon compared to IV sedation by £3833.76 per adult patient and by £2837.41 per paediatric patient. Clinical evidence indicated that Sedaconda ACD-S-delivered isoflurane sedation is associated with faster patient wake-up times than standard of care. Consequently, NICE recommended Sedaconda ACD-S as an option for delivering sedation in the ICU setting, but noted that further research should inform whether Sedaconda ACD-S-delivered sedation is of benefit to any particular subgroup of patients.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Cuidados Críticos
Límite:
Humans
País/Región como asunto:
Europa
Idioma:
En
Revista:
Appl Health Econ Health Policy
Asunto de la revista:
SAUDE PUBLICA
/
SERVICOS DE SAUDE
Año:
2024
Tipo del documento:
Article
Pais de publicación:
Nueva Zelanda